6ES7516-3UN00-0AB0 6ES7516-3UN00-0AB0 وحدة إيثرنت سيمنز S7-1500 إيثرنت

$9,800.00

  • رقم القطعة: 6ES7516-3UN00-0AB0
  • الشركة المصنعة:سيمنز
  • التوفر: In Stock
  • المهلة المقدرة: يشحن عادةً خلال 1-5 أيام عمل
  • الحالة: العلامة التجارية الجديدة
  • الضمان :12 شهراً
رمز المنتج: 6ES7516-3UN00-0AB0 التصنيفات: , الوسم:
الوصف
General information
Product type designation CPU 1516TF-3 PN/DP
HW functional status FS11
Firmware version V3.1
● FW update possible نعم
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode Yes; Distributed and central; with minimum OB 6x cycle of 375 µs (distributed) and 1 ms (central)
● SysLog نعم
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V19 (FW V3.1) / V15 (FW V2.5) or higher
Configuration control
via dataset نعم
العرض
Screen diagonal [cm] 6.1 cm
Control elements
Number of keys 6
Mode selector switch 1
جهد الإمداد
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
حماية القطبية العكسية نعم
Mains buffering
● Mains/voltage failure stored energy time 5 ms
● Repeat rate, min. 1/s
Input current
Current consumption (rated value) 1.2 A
Current consumption, max. 1.5 A
Inrush current, max. 1.9 A; Rated value
I²t 0.4 A²·s
Power
Infeed power to the backplane bus 12 W
Power consumption from the backplane bus (balanced) 30 W
Power loss
Power loss, typ. 24 W
Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required نعم
Work memory
● integrated (for program) 3 Mbyte
● integrated (for data) 7.5 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup
● maintenance-free نعم
CPU processing times
for bit operations, typ. 6 ns
for word operations, typ. 7 ns
for fixed point arithmetic, typ. 9 ns
for floating point arithmetic, typ. 37 ns
CPU-blocks
Number of elements (total) 8 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range 1 … 60 999; subdivided into: number range that can be used by the user: 1 … 59 999, and number range of DBs created via SFC 86: 60 000 … 60 999
● Size, max. 7.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range 0 … 65 535
● Size, max. 1 Mbyte
FC
● Number range 0 … 65 535
● Size, max. 1 Mbyte
OB
● Size, max. 1 Mbyte
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 250 µs
● Number of process alarm OBs 50
● Number of DPV1 alarm OBs 3
● Number of isochronous mode OBs 3
● Number of technology synchronous alarm OBs 2
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2
● Number of diagnostic alarm OBs 1
Nesting depth
● per priority class 24; Up to 8 possible for F-blocks
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— adjustable نعم
IEC counter
● Number Any (only limited by the main memory)
Retentivity
— adjustable نعم
S7 times
● Number 2 048
Retentivity
— adjustable نعم
IEC timer
● Number Any (only limited by the main memory)
Retentivity
— adjustable نعم
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB
Extended retentive data area (incl. timers, counters, flags), max. 7.5 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Flag
● Size, max. 16 kbyte
● Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustable نعم
● Retentivity preset لا يوجد
Local data
● per priority class, max. 64 kbyte; max. 16 KB per block
Address area
Number of IO modules 8 192; max. number of modules / submodules
I/O address area
● Inputs 32 kbyte; All inputs are in the process image
● Outputs 32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
per CM/CP
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
Subprocess images
● Number of subprocess images, max. 32
Hardware configuration
Number of distributed IO systems 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
● integrated 1
● Via CM 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Number of IO Controllers
● integrated 2
● Via CM 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Rack
● Modules per rack, max. 32; CPU + 31 modules
● Number of lines, max. 1
PtP CM
● Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots
Time of day
Clock
● Type Hardware clock
● Backup time 6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max. 10 s; Typ.: 2 s
Operating hours counter
● Number 16
Clock synchronization
● supported نعم
● to DP, master نعم
● on DP, device نعم
● in AS, master نعم
● in AS, device نعم
● on Ethernet via NTP نعم
الواجهات
Number of PROFINET interfaces 2
Number of PROFIBUS interfaces 1
1. Interface
Interface types
● RJ 45 (Ethernet) Yes; X1
● Number of ports 2
● integrated switch نعم
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller نعم
● PROFINET IO Device نعم
● SIMATIC communication نعم
● Open IE communication Yes; Optionally also encrypted
● Web server نعم
● Media redundancy نعم
PROFINET IO Controller
Services
— Isochronous mode نعم
— Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional)
— IRT نعم
— PROFIenergy Yes; per user program
— Prioritized startup Yes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max. 256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max. 64
— Number of connectable IO Devices for RT, max. 256
— of which in line, max. 256
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces
— Number of IO Devices per tool, max. 8
— Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— PROFINET Security Class 1
Update time for IRT
— for send cycle of 250 µs 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 375 µs of the isochronous OB is decisive
— for send cycle of 500 µs 500 µs to 8 ms
— for send cycle of 1 ms 1 ms to 16 ms
— for send cycle of 2 ms 2 ms to 32 ms
— for send cycle of 4 ms 4 ms to 64 ms
— With IRT and parameterization of “odd” send cycles Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3 875 µs)
Update time for RT
— for send cycle of 250 µs 250 µs to 128 ms
— for send cycle of 500 µs 500 µs to 256 ms
— for send cycle of 1 ms 1 ms to 512 ms
— for send cycle of 2 ms 2 ms to 512 ms
— for send cycle of 4 ms 4 ms to 512 ms
PROFINET IO Device
Services
— Isochronous mode لا يوجد
— IRT نعم
— PROFIenergy Yes; per user program
— Shared device نعم
— Number of IO Controllers with shared device, max. 4
— activation/deactivation of I-devices Yes; per user program
— Asset management record Yes; per user program
— PROFINET Security Class SNMP Configuration and DCP Read Only
2. Interface
Interface types
● RJ 45 (Ethernet) Yes; X2
● Number of ports 1
● integrated switch لا يوجد
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller نعم
● PROFINET IO Device نعم
● SIMATIC communication نعم
● Open IE communication Yes; Optionally also encrypted
● Web server نعم
● Media redundancy لا يوجد
PROFINET IO Controller
Services
— Isochronous mode لا يوجد
— Direct data exchange لا يوجد
— IRT لا يوجد
— PROFIenergy Yes; per user program
— Prioritized startup لا يوجد
— Number of connectable IO Devices, max. 32; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Number of connectable IO Devices for RT, max. 32
— of which in line, max. 32
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces
— Number of IO Devices per tool, max. 8
— Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— PROFINET Security Class 1
Update time for RT
— for send cycle of 1 ms 1 ms to 512 ms
PROFINET IO Device
Services
— Isochronous mode لا يوجد
— IRT لا يوجد
— PROFIenergy Yes; per user program
— Prioritized startup لا يوجد
— Shared device نعم
— Number of IO Controllers with shared device, max. 4
— activation/deactivation of I-devices Yes; per user program
— Asset management record Yes; per user program
— PROFINET Security Class SNMP Configuration and DCP Read Only
3. Interface
Interface types
● RS 485 Yes; X3
● Number of ports 1
Protocols
● PROFIBUS DP master نعم
● PROFIBUS DP device لا يوجد
● SIMATIC communication نعم
PROFIBUS DP master
● Number of connections, max. 48; for the integrated PROFIBUS DP interface
● max. number of DP devices 125; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
Services
— Equidistance نعم
— Isochronous mode نعم
— activation/deactivation of DP devices نعم
Interface types
RJ 45 (Ethernet)
● 100 Mbps نعم
● Autonegotiation نعم
● Autocrossing نعم
● Industrial Ethernet status LED نعم
RS 485
● Transmission rate, max. 12 Mbit/s
Protocols
PROFIsafe Yes; V2.4 / V2.6
Number of connections
● Number of connections, max. 256; via integrated interfaces of the CPU and connected CPs / CMs
● Number of connections reserved for ES/HMI/web 10
● Number of connections via integrated interfaces 128
● Number of S7 routing paths 16
Redundancy mode
● H-Sync forwarding نعم
Media redundancy
— Media redundancy only via 1st interface (X1)
— MRP Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
— MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0
— MRPD Yes; Requirement: IRT
— Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max. 50
SIMATIC communication
● PG/OP communication Yes; encryption with TLS V1.3 pre-selected
● S7 routing نعم
● Data record routing نعم
● S7 communication, as server نعم
● S7 communication, as client نعم
● User data per job, max. See online help (S7 communication, user data size)
Open IE communication
● TCP/IP نعم
— Data length, max. 64 kbyte
— several passive connections per port, supported نعم
● ISO-on-TCP (RFC1006) نعم
— Data length, max. 64 kbyte
● UDP نعم
— Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicast Yes; Max. 5 multicast circuits
● DHCP نعم
● DNS نعم
● SNMP نعم
● DCP نعم
● LLDP نعم
● Encryption Yes; Optional
Web server
● HTTP Yes; Standard and user pages
● HTTPS Yes; Standard and user pages
● web API
— Number of sessions, max. 200
— number of simultaneous HTTP calls, max. 4
— HTTP request body, max. 131 072 byte
OPC UA
● Runtime license required Yes; “Medium” license required
● OPC UA Client Yes; Data Access (registered Read/Write), Method Call
— Application authentication نعم
— Security policies Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication “anonymous” or by user name & password
— Number of connections, max. 10
— Number of nodes of the client interfaces, recommended max. 2 000
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max. 300
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. 20
— Number of elements for one call of OPC_UA_MethodGetHandleList, max. 100
— Number of simultaneous calls of the client instructions for session management, per connection, max. 1
— Number of simultaneous calls of the client instructions for data access, per connection, max. 5
— Number of registerable nodes, max. 5 000
— Number of registerable method calls of OPC_UA_MethodCall, max. 100
— Number of inputs/outputs when calling OPC_UA_MethodCall, max. 20
● OPC UA Server Yes; Data Access (Read, Write, Subscribe), Method Call, Alarms & Condition (A&C), Custom Address Space
— Application authentication نعم
— Security policies available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss
— User authentication “anonymous” or by user name & password
— GDS support (certificate management) نعم
— Number of sessions, max. 48
— Number of accessible variables, max. 100 000
— Number of registerable nodes, max. 20 000
— Number of subscriptions per session, max. 50
— Sampling interval, min. 100 ms
— Publishing interval, min. 100 ms
— Number of server methods, max. 50
— Number of inputs/outputs per server method, max. 20
— Number of monitored items, recommended max. 4 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max. 10 of each “Server interfaces” / “Companion specification” type and 20 of the type “Reference namespace”
— Number of nodes for user-defined server interfaces, max. 30 000
● Alarms and Conditions نعم
— Number of program alarms 200
— Number of alarms for system diagnostics 100
Further protocols
● MODBUS Yes; MODBUS TCP
Isochronous mode
Equidistance نعم
S7 message functions
Number of login stations for message functions, max. 64
number of subscriptions, max. 500
number of tags/attributes for subscriptions, max. 8 000
Program alarms نعم
Number of configurable program messages, max. 10 000; Program messages are generated by the “Program_Alarm” block, ProDiag or GRAPH
Number of loadable program messages in RUN, max. 10 000
Number of simultaneously active program alarms
● Number of program alarms 1 000
● Number of alarms for system diagnostics 200
● Number of alarms for motion technology objects 480
Test commissioning functions
Joint commission (Team Engineering) Yes; Parallel online access possible for up to 8 engineering systems
Status block Yes; Up to 8 simultaneously (in total across all ES clients)
Single step لا يوجد
Number of breakpoints 8
Profiling لا يوجد
Status/control
● Status/control variable Yes; without fail-safe
● Variables inputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters
● Number of variables, max.
— of which status variables, max. 200; per job
— of which control variables, max. 200; per job
Forcing
● Forcing Yes; without fail-safe
● Forcing, variables peripheral inputs/outputs (without fail-safe)
● Number of variables, max. 200
Diagnostic buffer
● present نعم
● Number of entries, max. 3 200
— of which powerfail-proof 500
Traces
● Number of configurable Traces 4
● Memory size per trace, max. 512 kbyte
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LED نعم
● ERROR LED نعم
● MAINT LED نعم
● Connection display LINK TX/RX نعم
Supported technology objects
Motion Control Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
● Number of available Motion Control resources for technology objects 6 400
● Required Motion Control resources
— per speed-controlled axis 40
— per positioning axis 80
— per synchronous axis 160
— per external encoder 80
— per output cam 20
— per cam track 160
— per probe 40
● Number of available Extended Motion Control resources for technology objects 192
● Required Extended Motion Control resources
— per cam (1 000 points and 50 segments) 2
— per cam (10 000 points and 50 segments) 20
— for each set of kinematics 30
— per Interpreter 60
— Per leading axis proxy 3
● kinematics functions
— kinematics with up to 4 interpolating axes Yes; max. 3D + orientation
— kinematics with 5 or more interpolating axes لا يوجد
— user-defined kinematics نعم
— SIMATIC Safe Kinematics لا يوجد
● Positioning axis
— Number of positioning axes at motion control cycle of 4 ms (typical value) 55
— Number of positioning axes at motion control cycle of 8 ms (typical value) 80
المراقب المالي
● PID_Compact Yes; Universal PID controller with integrated optimization
● PID_3Step Yes; PID controller with integrated optimization for valves
● PID-Temp Yes; PID controller with integrated optimization for temperature
Counting and measuring
● High-speed counter نعم
Standards, approvals, certificates
Ecological footprint
● environmental product declaration نعم
Global warming potential
— global warming potential, (total) [CO2 eq] 570 kg
— global warming potential, (during production) [CO2 eq] 96.9 kg
— global warming potential, (during operation) [CO2 eq] 483 kg
— global warming potential, (after end of life cycle) [CO2 eq] -9.97 kg
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1 PLe
● SIL acc. to IEC 61508 SIL 3
Probability of failure (for service life of 20 years and repair time of 100 hours)
— Low demand mode: PFDavg in accordance with SIL3 < 2.00E-05
— High demand/continuous mode: PFH in accordance with SIL3 < 1.00E-09
الظروف المحيطة
Ambient temperature during operation
● horizontal installation, min. 0 °C
● horizontal installation, max. 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
● vertical installation, min. 0 °C
● vertical installation, max. 40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
configuration / header
configuration / programming / header
Programming language
— LAD Yes; incl. failsafe
— FBD Yes; incl. failsafe
— STL نعم
— SCL نعم
— CFC Yes; either CFC or failsafe functionality
— GRAPH نعم
Know-how protection
● User program protection/password protection نعم
● Copy protection نعم
● Block protection نعم
Access protection
● protection of confidential configuration data نعم
● Password for display نعم
● Protection level: Write protection نعم
● Protection level: Read/write protection نعم
● Protection level: Write protection for Failsafe نعم
● Protection level: Complete protection نعم
● User administration Yes; device-wide
programming / cycle time monitoring / header
● lower limit adjustable minimum cycle time
● upper limit adjustable maximum cycle time
الأبعاد
العرض 175 mm
الارتفاع 147 mm
العمق 129 mm
Weights
Weight, approx. 1 929 g
Classifications
Version Classification
eClass 14 27-24-22-07
eClass 12 27-24-22-07
eClass 9.1 27-24-22-07
eClass 9 27-24-22-07
eClass 8 27-24-22-07
eClass 7.1 27-24-22-07
eClass 6 27-24-22-07
ETIM 9 EC000236
ETIM 8 EC000236
ETIM 7 EC000236
IDEA 4 3565
UNSPSC 15 32-15-17-05
معلومات إضافية
الوزن 3 كيلوجرام
الأبعاد 40 × 30 × 20 سنتيميتر
مراجعات (0)

المراجعات

لا توجد مراجعات بعد.

كن أول من يقيم “6ES7516-3UN00-0AB0 Siemens S7-1500 Ethernet Module”
الشحن والتوصيل

1. معالجة الطلبات: تتم معالجة الطلبات في غضون يوم أو يومين عمل بعد تأكيد الدفع. تُستثنى عطلات نهاية الأسبوع والعطلات من أوقات المعالجة.
2. خيارات الشحن والجداول الزمنية :
أ- الشحن القياسي: 3-7 أيام عمل (تختلف حسب الوجهة).
ب- الشحن السريع: 2-3 أيام عمل (تطبق رسوم إضافية).
ج- الشحن الدولي: 7-15 يوم عمل (قد تؤثر الجمارك على التسليم).
الملاحظات:
بالنسبة للمنتجات المتوفرة في المخزن، نقوم بالشحن خلال 5 أيام عمل بعد استلام الدفع.
سيتم تأكيد الجداول الزمنية للمنتجات غير المتوفرة في المخزون أو المنتجات المخصصة عبر البريد الإلكتروني بعد تقديم الطلب.
3. تتبع طلبك: ستتلقى رقم تتبع عبر البريد الإلكتروني بمجرد شحن طلبك. استخدم بوابة حالة الطلب للتحقق من التحديثات في الوقت الفعلي.
4. مشاكل التسليم؟
عمليات التسليم الفاشلة: اتصل بشركة النقل المحلية أولاً، ثم تواصل معنا.
عناصر خاطئة/مفقودة؟ راسلنا عبر البريد الإلكتروني في غضون 7 أيام من التسليم مع تفاصيل الطلب.
5. ملاحظات هامة الجمارك والرسوم: المشترون الدوليون مسؤولون عن أي رسوم استيراد.
دقة العنوان: تحقق مرة أخرى من تفاصيل الشحن الخاصة بك - لا يمكننا تعديل الطلبات بمجرد معالجتها!

هل من أسئلة؟ زوروا موقعنا الأسئلة الشائعة أو اتصل بـ support@isscasolutions.com