General specifications
Product Name |
Eaton Moeller® series EMT6 Thermistor overload relay
|
Catalog Number |
269470
|
Model Code |
EMT6-K
|
EAN |
4015082694708
|
Product Length/Depth |
103 mm
|
Product Height |
83 mm
|
Product Width |
23 mm
|
Product Weight |
0.13 kg
|
Certifications |
CSA
CSA Class No.: 3211-03 IEC/EN 60947-8 UL Category Control No.: NKCR UL File No.: E29184 VDE 0660 CSA File No.: 12528 EN 55011 IEC/EN 61000-4-3 م IEC/EN 61000-4-2 CSA-C22.2 No. 14 UL UL 508 IEC/EN 60947 |
Product specifications
Air discharge |
8 kV
|
Electric connection type |
Screw connection
|
Pollution degree |
3
|
Power consumption |
2 W at DC
3.5 VA at AC |
Burst impulse |
2 kV, Supply cable
1 kV, Signal cable According to IEC/EN 61000-4-4 |
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Rated impulse withstand voltage (Uimp) |
4000 V AC
6000 V AC |
Ambient operating temperature – max |
60 °C
|
Ambient operating temperature – min |
-25 °C
|
Ambient operating temperature (enclosed) – max |
45 °C
|
Ambient operating temperature (enclosed) – min |
25 °C
|
Ambient storage temperature – max |
85 °C
|
Ambient storage temperature – min |
45 °C
|
Conventional thermal current ith of auxiliary contacts (1-pole, open) |
6 A
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
1
|
Number of contacts (normally open contacts) |
1
|
Number of measuring circuits |
1
|
Product category |
EMT6 thermistor overload relay for machine protection
|
Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
Rated control supply voltage (Us) at AC, 50 Hz – max |
240 V
|
Rated control supply voltage (Us) at AC, 50 Hz – min |
24 V
|
Rated control supply voltage (Us) at AC, 60 Hz – max |
240 V
|
Rated control supply voltage (Us) at AC, 60 Hz – min |
24 V
|
Rated control supply voltage (Us) at DC – max |
240 V
|
Rated control supply voltage (Us) at DC – min |
24 V
|
Rated operational current (Ie) |
3 A at AC-14, 400 V (NC)
3 A at AC-14, 380 V 400 V 415 V (NO) 1 A at AC-15, 300 V (NO) 3 A at AC-15, 220 V 230 V 240 V (NO) 1 A at AC-15, 380 V 400 V 415 V (NO) 3 A at AC-14, 300 V (NO) 1 A at AC-15, 300 V (NC) 3 A at AC-14, 300 V (NC) 3 A at AC-14, 380 V 400 V 415 V (NC) 1 A at AC-15, 380 V 400 V 415 V (NC) 3 A at AC-15, 220 V 230 V 240 V (NC) 3 A at AC-15, 220 V 230 V 240 V |
Degree of protection |
IP20
|
Functions |
Notifications of mains and faults via LED display
Short-circuit in the sensor cable Test function via separate button |
Screwdriver size |
1 x 6 mm, Terminal screw, Standard screwdriver
2, Terminal screw, Pozidriv screwdriver |
Voltage type |
AC/DC
|
Mounting position |
As required
|
Shock resistance |
10 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
|
Contact discharge |
6 kV, Electrostatic discharge (ESD)
|
Overvoltage category |
III
|
Short-circuit protection rating |
Max. 6 A gG/gL, Fuse, Contacts
|
Surge rating |
4 kV, asymmetrical, power pulses (Surge), EMC
According to IEC/EN 61000-4-5, power pulses (Surge), EMC 2 kV, symmetrical, power pulses (Surge), EMC |
Electromagnetic fields |
3 V/m at 1.4 – 2 GHz (according to IEC EN 61000-4-3)
1 V/m at 2.0 – 2.7 GHz (according to IEC EN 61000-4-3) 10 V/m at 80 – 1000 MHz (according to IEC EN 61000-4-3) |
Pick-up voltage |
0.85 – 1.1 V x Uₑ
|
Immunity to line-conducted interference |
10 V (according to IEC/EN 61000-4-6)
|
Radio interference class |
Class B (EN 55011)
|
Tightening torque |
1.2 Nm, Screw terminals
|
Safe isolation |
250 V AC, Between the contacts, According to EN 61140
250 V AC, Between the contacts and power supply, According to EN 61140 |
Screw size |
M3.5, Terminal screw
|
Rated insulation voltage (Ui) |
400 V
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Rated operational voltage (Ue) – max |
240 V
|
Reset resistance |
1600 Ω
|
Resistance measuring range – max |
12000 Ω
|
Resistance measuring range – min |
750 Ω
|
Static heat dissipation, non-current-dependent Pvs |
0.8 W
|
Temperature measuring range – max |
0 °C
|
Temperature measuring range – min |
0 °C
|
Trip resistance |
3600 Ω
|
Voltage rating – max |
600 V
|
Terminal capacity |
1 x (0.5 – 2.5) mm², solid
20 – 14 AWG, solid or stranded 2 x (0.5 – 1.5) mm², solid 1 x (0.5 – 2.5) mm², flexible with ferrule 2 x (0.5 – 1.5) mm², flexible with ferrule |
Rated switch current |
6 A
|
Supply voltage at AC, 50 Hz – min |
24 V
|
Supply voltage at AC, 50 Hz – max |
240 V
|
Supply voltage at AC, 60 Hz – min |
24 V
|
Supply voltage at AC, 60 Hz – max |
240 V
|
Supply voltage at DC – min |
24 V
|
Supply voltage at DC – max |
240 V
|
Operating voltage at AC, 50 Hz – min |
24 V
|
Operating voltage at AC, 50 Hz – max |
240 V
|
Operating voltage at AC, 60 Hz – min |
24 V
|
Operating voltage at AC, 60 Hz – max |
240 V
|
Operating voltage at DC – min |
24 V
|
Operating voltage at DC – max |
240 V
|
Voltage type of supply voltage |
AC/DC
|
Voltage type of operating voltage |
AC/DC
|
Connection type (auxiliary circuit) |
Screw connection
|
الوزن | 1 كيلوجرام |
---|---|
الأبعاد | 20 × 15 × 15 سنتيميتر |
يجب عليك تسجيل الدخول لنشر مراجعة.


1- تفاصيل التسليم: سنقوم بشحن جميع العناصر في غضون 1-5 أيام عمل عند استلام الدفع، هدفنا هو: شحنها بأسرع ما يمكن.
2-نحن نوفر التسليم في جميع أنحاء العالم باستخدام شركات الشحن مثل: DHL، FEDEX، UPS، إلى الولايات المتحدة الأمريكية، تحتاج إلى 3-4 أيام عمل، إلى بلدان أخرى، تحتاج إلى 4-8 أيام عمل عادة. ولكن في بعض الأحيان يعتمد التسليم الدولي بشكل كبير على شركة البريد السريع والجمارك / الرسوم المحلية.
3- عادةً ما يكون هناك تأخير في نظام تحديث التسليم؛ يمكنك التفكير في تتبع أغراضك في غضون أيام قليلة.
4- سيتم إرسال كل رقم التتبع إلى بريدك الإلكتروني على paypal بعد إرسال الطرد، إذا لم تستلمه بعد المهلة الزمنية، فلا تتردد في الاتصال بنا.
5- رسوم وضرائب الاستيراد غير مشمولة في سعر السلعة أو رسوم الشحن. هذه الرسوم هي مسؤولية المشتري.
المراجعات
لا توجد مراجعات بعد.