6ES7516-3UN00-0AB0 6ES7516-3UN00-0AB0 وحدة إيثرنت سيمنز S7-1500 إيثرنت

$9,800.00

  • رقم القطعة: 6ES7516-3UN00-0AB0
  • الشركة المصنعة:سيمنز
  • التوفر: In Stock
  • المهلة المقدرة: يشحن عادةً خلال 1-5 أيام عمل
  • الحالة: العلامة التجارية الجديدة
  • الضمان :12 شهراً
رمز المنتج: 6ES7516-3UN00-0AB0 التصنيفات: , الوسم:
الوصف
General information
Product type designationCPU 1516TF-3 PN/DP
HW functional statusFS11
Firmware versionV3.1
● FW update possibleنعم
Product function
● I&M dataYes; I&M0 to I&M3
● Isochronous modeYes; Distributed and central; with minimum OB 6x cycle of 375 µs (distributed) and 1 ms (central)
● SysLogنعم
Engineering with
● STEP 7 TIA Portal configurable/integrated from versionV19 (FW V3.1) / V15 (FW V2.5) or higher
Configuration control
via datasetنعم
Display
Screen diagonal [cm]6.1 cm
Control elements
Number of keys6
Mode selector switch1
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionنعم
Mains buffering
● Mains/voltage failure stored energy time5 ms
● Repeat rate, min.1/s
Input current
Current consumption (rated value)1.2 A
Current consumption, max.1.5 A
Inrush current, max.1.9 A; Rated value
I²t0.4 A²·s
Power
Infeed power to the backplane bus12 W
Power consumption from the backplane bus (balanced)30 W
Power loss
Power loss, typ.24 W
Memory
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredنعم
Work memory
● integrated (for program)3 Mbyte
● integrated (for data)7.5 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max.32 Gbyte
Backup
● maintenance-freeنعم
CPU processing times
for bit operations, typ.6 ns
for word operations, typ.7 ns
for fixed point arithmetic, typ.9 ns
for floating point arithmetic, typ.37 ns
CPU-blocks
Number of elements (total)8 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range1 … 60 999; subdivided into: number range that can be used by the user: 1 … 59 999, and number range of DBs created via SFC 86: 60 000 … 60 999
● Size, max.7.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range0 … 65 535
● Size, max.1 Mbyte
FC
● Number range0 … 65 535
● Size, max.1 Mbyte
OB
● Size, max.1 Mbyte
● Number of free cycle OBs100
● Number of time alarm OBs20
● Number of delay alarm OBs20
● Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 250 µs
● Number of process alarm OBs50
● Number of DPV1 alarm OBs3
● Number of isochronous mode OBs3
● Number of technology synchronous alarm OBs2
● Number of startup OBs100
● Number of asynchronous error OBs4
● Number of synchronous error OBs2
● Number of diagnostic alarm OBs1
Nesting depth
● per priority class24; Up to 8 possible for F-blocks
Counters, timers and their retentivity
S7 counter
● Number2 048
Retentivity
— adjustableنعم
IEC counter
● NumberAny (only limited by the main memory)
Retentivity
— adjustableنعم
S7 times
● Number2 048
Retentivity
— adjustableنعم
IEC timer
● NumberAny (only limited by the main memory)
Retentivity
— adjustableنعم
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB
Extended retentive data area (incl. timers, counters, flags), max.7.5 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Flag
● Size, max.16 kbyte
● Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustableنعم
● Retentivity presetNo
Local data
● per priority class, max.64 kbyte; max. 16 KB per block
Address area
Number of IO modules8 192; max. number of modules / submodules
I/O address area
● Inputs32 kbyte; All inputs are in the process image
● Outputs32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
per CM/CP
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
Subprocess images
● Number of subprocess images, max.32
Hardware configuration
Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
● integrated1
● Via CM8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Number of IO Controllers
● integrated2
● Via CM8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Rack
● Modules per rack, max.32; CPU + 31 modules
● Number of lines, max.1
PtP CM
● Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
Time of day
Clock
● TypeHardware clock
● Backup time6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max.10 s; Typ.: 2 s
Operating hours counter
● Number16
Clock synchronization
● supportedنعم
● to DP, masterنعم
● on DP, deviceنعم
● in AS, masterنعم
● in AS, deviceنعم
● on Ethernet via NTPنعم
Interfaces
Number of PROFINET interfaces2
Number of PROFIBUS interfaces1
1. Interface
Interface types
● RJ 45 (Ethernet)Yes; X1
● Number of ports2
● integrated switchنعم
Protocols
● IP protocolYes; IPv4
● PROFINET IO Controllerنعم
● PROFINET IO Deviceنعم
● SIMATIC communicationنعم
● Open IE communicationYes; Optionally also encrypted
● Web serverنعم
● Media redundancyنعم
PROFINET IO Controller
Services
— Isochronous modeنعم
— Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
— IRTنعم
— PROFIenergyYes; per user program
— Prioritized startupYes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max.256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max.64
— Number of connectable IO Devices for RT, max.256
— of which in line, max.256
— Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— PROFINET Security Class1
Update time for IRT
— for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 375 µs of the isochronous OB is decisive
— for send cycle of 500 µs500 µs to 8 ms
— for send cycle of 1 ms1 ms to 16 ms
— for send cycle of 2 ms2 ms to 32 ms
— for send cycle of 4 ms4 ms to 64 ms
— With IRT and parameterization of “odd” send cyclesUpdate time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3 875 µs)
Update time for RT
— for send cycle of 250 µs250 µs to 128 ms
— for send cycle of 500 µs500 µs to 256 ms
— for send cycle of 1 ms1 ms to 512 ms
— for send cycle of 2 ms2 ms to 512 ms
— for send cycle of 4 ms4 ms to 512 ms
PROFINET IO Device
Services
— Isochronous modeNo
— IRTنعم
— PROFIenergyYes; per user program
— Shared deviceنعم
— Number of IO Controllers with shared device, max.4
— activation/deactivation of I-devicesYes; per user program
— Asset management recordYes; per user program
— PROFINET Security ClassSNMP Configuration and DCP Read Only
2. Interface
Interface types
● RJ 45 (Ethernet)Yes; X2
● Number of ports1
● integrated switchNo
Protocols
● IP protocolYes; IPv4
● PROFINET IO Controllerنعم
● PROFINET IO Deviceنعم
● SIMATIC communicationنعم
● Open IE communicationYes; Optionally also encrypted
● Web serverنعم
● Media redundancyNo
PROFINET IO Controller
Services
— Isochronous modeNo
— Direct data exchangeNo
— IRTNo
— PROFIenergyYes; per user program
— Prioritized startupNo
— Number of connectable IO Devices, max.32; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Number of connectable IO Devices for RT, max.32
— of which in line, max.32
— Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— PROFINET Security Class1
Update time for RT
— for send cycle of 1 ms1 ms to 512 ms
PROFINET IO Device
Services
— Isochronous modeNo
— IRTNo
— PROFIenergyYes; per user program
— Prioritized startupNo
— Shared deviceنعم
— Number of IO Controllers with shared device, max.4
— activation/deactivation of I-devicesYes; per user program
— Asset management recordYes; per user program
— PROFINET Security ClassSNMP Configuration and DCP Read Only
3. Interface
Interface types
● RS 485Yes; X3
● Number of ports1
Protocols
● PROFIBUS DP masterنعم
● PROFIBUS DP deviceNo
● SIMATIC communicationنعم
PROFIBUS DP master
● Number of connections, max.48; for the integrated PROFIBUS DP interface
● max. number of DP devices125; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
Services
— Equidistanceنعم
— Isochronous modeنعم
— activation/deactivation of DP devicesنعم
Interface types
RJ 45 (Ethernet)
● 100 Mbpsنعم
● Autonegotiationنعم
● Autocrossingنعم
● Industrial Ethernet status LEDنعم
RS 485
● Transmission rate, max.12 Mbit/s
Protocols
PROFIsafeYes; V2.4 / V2.6
Number of connections
● Number of connections, max.256; via integrated interfaces of the CPU and connected CPs / CMs
● Number of connections reserved for ES/HMI/web10
● Number of connections via integrated interfaces128
● Number of S7 routing paths16
Redundancy mode
● H-Sync forwardingنعم
Media redundancy
— Media redundancyonly via 1st interface (X1)
— MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
— MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
— MRPDYes; Requirement: IRT
— Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max.50
SIMATIC communication
● PG/OP communicationYes; encryption with TLS V1.3 pre-selected
● S7 routingنعم
● Data record routingنعم
● S7 communication, as serverنعم
● S7 communication, as clientنعم
● User data per job, max.See online help (S7 communication, user data size)
Open IE communication
● TCP/IPنعم
— Data length, max.64 kbyte
— several passive connections per port, supportedنعم
● ISO-on-TCP (RFC1006)نعم
— Data length, max.64 kbyte
● UDPنعم
— Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicastYes; Max. 5 multicast circuits
● DHCPنعم
● DNSنعم
● SNMPنعم
● DCPنعم
● LLDPنعم
● EncryptionYes; Optional
Web server
● HTTPYes; Standard and user pages
● HTTPSYes; Standard and user pages
● web API
— Number of sessions, max.200
— number of simultaneous HTTP calls, max.4
— HTTP request body, max.131 072 byte
OPC UA
● Runtime license requiredYes; “Medium” license required
● OPC UA ClientYes; Data Access (registered Read/Write), Method Call
— Application authenticationنعم
— Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication“anonymous” or by user name & password
— Number of connections, max.10
— Number of nodes of the client interfaces, recommended max.2 000
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
— Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
— Number of simultaneous calls of the client instructions for session management, per connection, max.1
— Number of simultaneous calls of the client instructions for data access, per connection, max.5
— Number of registerable nodes, max.5 000
— Number of registerable method calls of OPC_UA_MethodCall, max.100
— Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
● OPC UA ServerYes; Data Access (Read, Write, Subscribe), Method Call, Alarms & Condition (A&C), Custom Address Space
— Application authenticationنعم
— Security policiesavailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss
— User authentication“anonymous” or by user name & password
— GDS support (certificate management)نعم
— Number of sessions, max.48
— Number of accessible variables, max.100 000
— Number of registerable nodes, max.20 000
— Number of subscriptions per session, max.50
— Sampling interval, min.100 ms
— Publishing interval, min.100 ms
— Number of server methods, max.50
— Number of inputs/outputs per server method, max.20
— Number of monitored items, recommended max.4 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max.10 of each “Server interfaces” / “Companion specification” type and 20 of the type “Reference namespace”
— Number of nodes for user-defined server interfaces, max.30 000
● Alarms and Conditionsنعم
— Number of program alarms200
— Number of alarms for system diagnostics100
Further protocols
● MODBUSYes; MODBUS TCP
Isochronous mode
Equidistanceنعم
S7 message functions
Number of login stations for message functions, max.64
number of subscriptions, max.500
number of tags/attributes for subscriptions, max.8 000
Program alarmsنعم
Number of configurable program messages, max.10 000; Program messages are generated by the “Program_Alarm” block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.10 000
Number of simultaneously active program alarms
● Number of program alarms1 000
● Number of alarms for system diagnostics200
● Number of alarms for motion technology objects480
Test commissioning functions
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 8 engineering systems
Status blockYes; Up to 8 simultaneously (in total across all ES clients)
Single stepNo
Number of breakpoints8
ProfilingNo
Status/control
● Status/control variableYes; without fail-safe
● Variablesinputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters
● Number of variables, max.
— of which status variables, max.200; per job
— of which control variables, max.200; per job
Forcing
● ForcingYes; without fail-safe
● Forcing, variablesperipheral inputs/outputs (without fail-safe)
● Number of variables, max.200
Diagnostic buffer
● presentنعم
● Number of entries, max.3 200
— of which powerfail-proof500
Traces
● Number of configurable Traces4
● Memory size per trace, max.512 kbyte
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LEDنعم
● ERROR LEDنعم
● MAINT LEDنعم
● Connection display LINK TX/RXنعم
Supported technology objects
Motion ControlYes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
● Number of available Motion Control resources for technology objects6 400
● Required Motion Control resources
— per speed-controlled axis40
— per positioning axis80
— per synchronous axis160
— per external encoder80
— per output cam20
— per cam track160
— per probe40
● Number of available Extended Motion Control resources for technology objects192
● Required Extended Motion Control resources
— per cam (1 000 points and 50 segments)2
— per cam (10 000 points and 50 segments)20
— for each set of kinematics30
— per Interpreter60
— Per leading axis proxy3
● kinematics functions
— kinematics with up to 4 interpolating axesYes; max. 3D + orientation
— kinematics with 5 or more interpolating axesNo
— user-defined kinematicsنعم
— SIMATIC Safe KinematicsNo
● Positioning axis
— Number of positioning axes at motion control cycle of 4 ms (typical value)55
— Number of positioning axes at motion control cycle of 8 ms (typical value)80
المراقب المالي
● PID_CompactYes; Universal PID controller with integrated optimization
● PID_3StepYes; PID controller with integrated optimization for valves
● PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuring
● High-speed counterنعم
Standards, approvals, certificates
Ecological footprint
● environmental product declarationنعم
Global warming potential
— global warming potential, (total) [CO2 eq]570 kg
— global warming potential, (during production) [CO2 eq]96.9 kg
— global warming potential, (during operation) [CO2 eq]483 kg
— global warming potential, (after end of life cycle) [CO2 eq]-9.97 kg
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1PLe
● SIL acc. to IEC 61508SIL 3
Probability of failure (for service life of 20 years and repair time of 100 hours)
— Low demand mode: PFDavg in accordance with SIL3< 2.00E-05
— High demand/continuous mode: PFH in accordance with SIL3< 1.00E-09
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.0 °C
● horizontal installation, max.60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
● vertical installation, min.0 °C
● vertical installation, max.40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
Ambient temperature during storage/transportation
● min.-40 °C
● max.70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
configuration / header
configuration / programming / header
Programming language
— LADYes; incl. failsafe
— FBDYes; incl. failsafe
— STLنعم
— SCLنعم
— CFCYes; either CFC or failsafe functionality
— GRAPHنعم
Know-how protection
● User program protection/password protectionنعم
● Copy protectionنعم
● Block protectionنعم
Access protection
● protection of confidential configuration dataنعم
● Password for displayنعم
● Protection level: Write protectionنعم
● Protection level: Read/write protectionنعم
● Protection level: Write protection for Failsafeنعم
● Protection level: Complete protectionنعم
● User administrationYes; device-wide
programming / cycle time monitoring / header
● lower limitadjustable minimum cycle time
● upper limitadjustable maximum cycle time
Dimensions
العرض175 mm
الارتفاع147 mm
العمق129 mm
Weights
Weight, approx.1 929 g
Classifications
VersionClassification
eClass1427-24-22-07
eClass1227-24-22-07
eClass9.127-24-22-07
eClass927-24-22-07
eClass827-24-22-07
eClass7.127-24-22-07
eClass627-24-22-07
ETIM9EC000236
ETIM8EC000236
ETIM7EC000236
IDEA43565
UNSPSC1532-15-17-05
معلومات إضافية
الوزن 3 كيلوجرام
الأبعاد 40 × 30 × 20 سنتيميتر
مراجعات (0)

المراجعات

لا توجد مراجعات بعد.

كن أول من يقيم “6ES7516-3UN00-0AB0 Siemens S7-1500 Ethernet Module”
الشحن والتوصيل

1. معالجة الطلبات: تتم معالجة الطلبات في غضون يوم أو يومين عمل بعد تأكيد الدفع. تُستثنى عطلات نهاية الأسبوع والعطلات من أوقات المعالجة.
2. خيارات الشحن والجداول الزمنية :
أ- الشحن القياسي: 3-7 أيام عمل (تختلف حسب الوجهة).
ب- الشحن السريع: 2-3 أيام عمل (تطبق رسوم إضافية).
ج- الشحن الدولي: 7-15 يوم عمل (قد تؤثر الجمارك على التسليم).
الملاحظات:
بالنسبة للمنتجات المتوفرة في المخزن، نقوم بالشحن خلال 5 أيام عمل بعد استلام الدفع.
سيتم تأكيد الجداول الزمنية للمنتجات غير المتوفرة في المخزون أو المنتجات المخصصة عبر البريد الإلكتروني بعد تقديم الطلب.
3. تتبع طلبك: ستتلقى رقم تتبع عبر البريد الإلكتروني بمجرد شحن طلبك. استخدم بوابة حالة الطلب للتحقق من التحديثات في الوقت الفعلي.
4. مشاكل التسليم؟
عمليات التسليم الفاشلة: اتصل بشركة النقل المحلية أولاً، ثم تواصل معنا.
عناصر خاطئة/مفقودة؟ راسلنا عبر البريد الإلكتروني في غضون 7 أيام من التسليم مع تفاصيل الطلب.
5. ملاحظات هامة الجمارك والرسوم: المشترون الدوليون مسؤولون عن أي رسوم استيراد.
دقة العنوان: تحقق مرة أخرى من تفاصيل الشحن الخاصة بك - لا يمكننا تعديل الطلبات بمجرد معالجتها!

هل من أسئلة؟ زوروا موقعنا الأسئلة الشائعة أو اتصل بـ support@isscasolutions.com