Eaton Moeller FAZ-C4/3 Miniatur-Leistungsschalter
$110.00
- Teil Nummer: FAZ-C4/3
- Hersteller:Eaton Moeller
- Verfügbarkeit: Nicht auf Lager
- Geschätzte Vorlaufzeit: 1-2Woche
- Zustand: Brandneu
- Garantie :12 Monate
Information
Eaton Moeller series xEffect – FAZ MCB. FAZ, 3-pole, tripping characteristic: C, rated current In: 4 A
Technical Specifications
Produkt Länge/Tiefe
80 mm
Produkthöhe
75.5 mm
Produkt Breite
54 mm
Produkt Gewicht
0.338 kg
Compliances
UL CSA09 (with supplementary protector only)
RoHS conform
Zertifizierungen
CSA (Class No. 3215-30)
UL 1077
UL (File No. E177451)
North America (UL recognized, CSA certified)
IEC/EN 60947-2
IEC/EN 60898
CSA-C22.2 No. 235
UL (Category Control Number QVNU2, QVNU8)
CSA (File No. 204453)
CE marking
EN45545-2
IEC 61373
Nennbetriebsstrom bei spezifizierter Wärmeableitung (In)
4 A
10.11 Short-circuit rating
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
Voltage rating (IEC/EN 60898-1)
415 VAC
10.4 Clearances and creepage distances
Meets the product standard’s requirements.
Rated short-circuit breaking capacity (EN 60898) at 230 V
10 kA
10.12 Electromagnetic compatibility
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
Mounting Method
Top-hat rail IEC/EN 60715
Current limiting class
3
Rated short-circuit breaking capacity (EN 60898) at 400 V
10 kA
Amperage Rating
4 A
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
Terminal capacity of screw terminals for main cable
10 mm² (2x)
Frequency rating – max
60 Hz
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard’s requirements.
10.8 Connections for external conductors
Is the panel builder’s responsibility.
Rated short-circuit breaking capacity (IEC 60947-2) at 400 V
15 kA
Number of poles (total)
3
Terminal protection
Finger and hand touch safe, DGUV VS3, EN 50274
Rated short-circuit breaking capacity (IEC 60947-2) at 230 V
15 kA
Special features
Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity
Betriebsumgebungstemperatur - max.
75 °C
Heat dissipation per pole, current-dependent
0 W
Built-in depth
70.5 mm
Rated switching capacity (IEC/EN 60898-1)
10 kA
Features
Additional equipment possible
Lifespan, electrical
10000 operations
Rated switching capacity (IEC/EN 60947-2) at max voltage rating
10 kA
Connectable conductor cross section (solid-core) – min
1 mm²
10.9.3 Impulse withstand voltage
Is the panel builder’s responsibility.
Number of poles
Three-pole
Betriebsumgebungstemperatur - min
-25 °C
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
Selectivity class
3
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Terminal capacity (control cable)
25 mm² (1x)
Used with
FAZ
Miniature circuit breaker
Einbaulage
Nach Bedarf
Equipment heat dissipation, current-dependent
4.4 W
Tripping characteristic
C
Frequency rating – min
50 Hz
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder’s responsibility.
Static heat dissipation, non-current-dependent
0 W
Application
Branch circuits, not as BCPD
Switchgear for industrial and advanced commercial applications
xEffect – Switchgear for industrial and advanced commercial applications
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Spannungstyp
AC
Number of poles (protected)
3
Frame
45 mm
Terminals (top and bottom)
Twin-purpose terminals
Heat dissipation capacity
0 W
Release characteristic
C
Width in number of modular spacings
3
Busbar material thickness
0.8 mm – 2 mm
Power loss
4.5 W
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard’s requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard’s requirements.
Enclosure width
80 mm
Voltage rating
240 V AC / 415 V AC
10.9.2 Power-frequency electric strength
Is the panel builder’s responsibility.
Connectable conductor cross section (solid-core) – max
25 mm²
Grad des Schutzes
IP20 (IEC)
UL/CSA Type: –
IP40 (when fitted)
IP20
Überspannungskategorie
III
Grad der Verschmutzung
2
10.7 Internal electrical circuits and connections
Is the panel builder’s responsibility.
Connectable conductor cross section (multi-wired) – min
1 mm²
Bemessungs-Stoßspannungsfestigkeit (Uimp)
4 kV
Operational voltage (IEC/EN 60947-2) – max
440 VAC
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Voltage rating at DC
60 V DC (per pole)
Admissible back-up fuse – max
125 A gL/gG
Voltage rating (UL)
480Y/277 V
Rated switching capacity (IEC/EN 60947-2)
15 kA
Voltage rating (UL CSA 13)
480 Y/277 V AC
Connectable conductor cross section (multi-wired) – max
25 mm²
Mounting width per pole
17.5 mm
Type
FAZ
Miniature circuit breaker
10.2.2 Corrosion resistance
Meets the product standard’s requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard’s requirements.
10.2.7 Inscriptions
Meets the product standard’s requirements.
Operational switching capacity
7.5 kA
Breaking capacity
10 kA (UL1077)
Direction of incoming supply
Nach Bedarf
Nennbetriebsspannung (Ue) - max
400 V
Rated service short-circuit breaking capacity (IEC/EN 60898-1)
7.5 kA
Mounting width
17.5 mm
Rated service short-circuit breaking capacity (IEC/EN 60947-2)
7.5 kA
Bemessungsisolationsspannung (Ui)
440 V
Gewicht | 1 kg |
---|---|
Größe | 20 × 15 × 15 cm |
Du musst angemeldet sein, um eine Bewertung abgeben zu können.


1. Auftragsabwicklung: Bestellungen werden innerhalb von 1-2 Werktagen nach Zahlungsbestätigung bearbeitet. Wochenenden und Feiertage sind von den Bearbeitungszeiten ausgenommen.
2. Versandoptionen und -fristen :
a. Standardversand: 3-7 Werktage (variiert je nach Zielort).
b. Eilversand: 2-3 Werktage (es fallen zusätzliche Gebühren an).
c.Internationaler Versand: 7-15 Arbeitstage (der Zoll kann die Lieferung beeinträchtigen).
Anmerkungen:
Für vorrätige Artikel versenden wir innerhalb von 5 Werktagen nach Zahlungseingang.
Bei Produkten, die nicht auf Lager sind, oder bei Sonderanfertigungen werden die Fristen nach der Bestellung per E-Mail bestätigt.
3. Verfolgung Ihrer Bestellung: Sie erhalten eine Tracking-Nummer per E-Mail, sobald Ihre Bestellung versandt wird. Nutzen Sie unser Auftragsstatus-Portal, um Echtzeit-Updates zu erhalten.
4. Probleme bei der Zustellung?
Fehlgeschlagene Lieferungen: Wenden Sie sich zunächst an Ihren örtlichen Spediteur und dann an uns.
Falsche/fehlende Artikel? Senden Sie uns innerhalb von 7 Tagen nach der Lieferung eine E-Mail mit den Bestelldaten.
5. Wichtige Hinweise Zölle und Abgaben: Internationale Käufer sind für alle Einfuhrgebühren verantwortlich.
Korrekte Adresse: Überprüfen Sie Ihre Versanddaten - wir können einmal bearbeitete Bestellungen nicht mehr ändern!
Noch Fragen? Besuchen Sie unser FAQs oder kontaktieren: support@isscasolutions.com
Bewertungen
Es gibt noch keine Bewertungen.