269470 Model code: EMT6-K Eaton Overload Relay 1NO + 1NC
$215.00
- Número de pieza: EMT6-K
- Fabricante:Eaton
- Disponibilidad: Agotado
- Tiempo estimado de entrega: 1-2 semanas
- Estado: Nuevo
- Garantía :12 meses
General specifications
Product Name |
Eaton Moeller® series EMT6 Thermistor overload relay
|
Catalog Number |
269470
|
Model Code |
EMT6-K
|
EAN |
4015082694708
|
Product Length/Depth |
103 mm
|
Product Height |
83 mm
|
Product Width |
23 mm
|
Product Weight |
0.13 kg
|
Certifications |
CSA
CSA Class No.: 3211-03 IEC/EN 60947-8 UL Category Control No.: NKCR UL File No.: E29184 VDE 0660 CSA File No.: 12528 EN 55011 IEC/EN 61000-4-3 CE IEC/EN 61000-4-2 CSA-C22.2 No. 14 UL UL 508 IEC/EN 60947 |
Product specifications
Air discharge |
8 kV
|
Electric connection type |
Screw connection
|
Pollution degree |
3
|
Consumo de energía |
2 W at DC
3.5 VA at AC |
Burst impulse |
2 kV, Supply cable
1 kV, Signal cable According to IEC/EN 61000-4-4 |
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78 |
Rated impulse withstand voltage (Uimp) |
4000 V AC
6000 V AC |
Ambient operating temperature – max |
60 °C
|
Ambient operating temperature – min |
-25 °C
|
Ambient operating temperature (enclosed) – max |
45 °C
|
Ambient operating temperature (enclosed) – min |
25 °C
|
Ambient storage temperature – max |
85 °C
|
Ambient storage temperature – min |
45 °C
|
Conventional thermal current ith of auxiliary contacts (1-pole, open) |
6 A
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
1
|
Number of contacts (normally open contacts) |
1
|
Number of measuring circuits |
1
|
Product category |
EMT6 thermistor overload relay for machine protection
|
Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
Rated control supply voltage (Us) at AC, 50 Hz – max |
240 V
|
Rated control supply voltage (Us) at AC, 50 Hz – min |
24 V
|
Rated control supply voltage (Us) at AC, 60 Hz – max |
240 V
|
Rated control supply voltage (Us) at AC, 60 Hz – min |
24 V
|
Rated control supply voltage (Us) at DC – max |
240 V
|
Rated control supply voltage (Us) at DC – min |
24 V
|
Rated operational current (Ie) |
3 A at AC-14, 400 V (NC)
3 A at AC-14, 380 V 400 V 415 V (NO) 1 A at AC-15, 300 V (NO) 3 A at AC-15, 220 V 230 V 240 V (NO) 1 A at AC-15, 380 V 400 V 415 V (NO) 3 A at AC-14, 300 V (NO) 1 A at AC-15, 300 V (NC) 3 A at AC-14, 300 V (NC) 3 A at AC-14, 380 V 400 V 415 V (NC) 1 A at AC-15, 380 V 400 V 415 V (NC) 3 A at AC-15, 220 V 230 V 240 V (NC) 3 A at AC-15, 220 V 230 V 240 V |
Grado de protección |
IP20
|
Functions |
Notifications of mains and faults via LED display
Short-circuit in the sensor cable Test function via separate button |
Screwdriver size |
1 x 6 mm, Terminal screw, Standard screwdriver
2, Terminal screw, Pozidriv screwdriver |
Voltage type |
AC/DC
|
Posición de montaje |
As required
|
Shock resistance |
10 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
|
Contact discharge |
6 kV, Electrostatic discharge (ESD)
|
Overvoltage category |
III
|
Short-circuit protection rating |
Max. 6 A gG/gL, Fuse, Contacts
|
Surge rating |
4 kV, asymmetrical, power pulses (Surge), EMC
According to IEC/EN 61000-4-5, power pulses (Surge), EMC 2 kV, symmetrical, power pulses (Surge), EMC |
Electromagnetic fields |
3 V/m at 1.4 – 2 GHz (according to IEC EN 61000-4-3)
1 V/m at 2.0 – 2.7 GHz (according to IEC EN 61000-4-3) 10 V/m at 80 – 1000 MHz (according to IEC EN 61000-4-3) |
Pick-up voltage |
0.85 – 1.1 V x Uₑ
|
Immunity to line-conducted interference |
10 V (according to IEC/EN 61000-4-6)
|
Radio interference class |
Class B (EN 55011)
|
Tightening torque |
1.2 Nm, Screw terminals
|
Safe isolation |
250 V AC, Between the contacts, According to EN 61140
250 V AC, Between the contacts and power supply, According to EN 61140 |
Screw size |
M3.5, Terminal screw
|
Rated insulation voltage (Ui) |
400 V
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Rated operational voltage (Ue) – max |
240 V
|
Reset resistance |
1600 Ω
|
Resistance measuring range – max |
12000 Ω
|
Resistance measuring range – min |
750 Ω
|
Static heat dissipation, non-current-dependent Pvs |
0.8 W
|
Temperature measuring range – max |
0 °C
|
Temperature measuring range – min |
0 °C
|
Trip resistance |
3600 Ω
|
Voltage rating – max |
600 V
|
Terminal capacity |
1 x (0.5 – 2.5) mm², solid
20 – 14 AWG, solid or stranded 2 x (0.5 – 1.5) mm², solid 1 x (0.5 – 2.5) mm², flexible with ferrule 2 x (0.5 – 1.5) mm², flexible with ferrule |
Rated switch current |
6 A
|
Supply voltage at AC, 50 Hz – min |
24 V
|
Supply voltage at AC, 50 Hz – max |
240 V
|
Supply voltage at AC, 60 Hz – min |
24 V
|
Supply voltage at AC, 60 Hz – max |
240 V
|
Supply voltage at DC – min |
24 V
|
Supply voltage at DC – max |
240 V
|
Operating voltage at AC, 50 Hz – min |
24 V
|
Operating voltage at AC, 50 Hz – max |
240 V
|
Operating voltage at AC, 60 Hz – min |
24 V
|
Operating voltage at AC, 60 Hz – max |
240 V
|
Operating voltage at DC – min |
24 V
|
Operating voltage at DC – max |
240 V
|
Tipo de tensión de alimentación |
AC/DC
|
Voltage type of operating voltage |
AC/DC
|
Connection type (auxiliary circuit) |
Screw connection
|
Peso | 1 kg |
---|---|
Dimensiones | 20 × 15 × 15 cm |
Debes acceder para publicar una valoración.


1. Tramitación de pedidos: Los pedidos se tramitan en un plazo de 1 a 2 días laborables tras la confirmación del pago. Los fines de semana y los días festivos no se tienen en cuenta.
2. Opciones de envío y plazos :
a.Envío estándar: 3-7 días laborables (varía según el destino).
b.Envío urgente: 2-3 días laborables (se aplicarán tarifas adicionales).
c.Envíos internacionales: 7-15 días laborables (las aduanas pueden afectar a la entrega).
Notas:
Para los artículos en stock, enviamos dentro de 5 días hábiles después de recibir el pago.
Los plazos de entrega de los productos fuera de stock o personalizados se confirmarán por correo electrónico tras la realización del pedido.
3. Seguimiento de su pedido: Recibirá un número de seguimiento por correo electrónico cuando se envíe su pedido. Utilice nuestro portal de estado de pedidos para comprobar las actualizaciones en tiempo real.
4. ¿Problemas de entrega?
Entregas fallidas: Contacte primero con su transportista local y después con nosotros.
¿Se ha equivocado o le faltan artículos? Envíenos un correo electrónico dentro de los 7 días de la entrega con los detalles del pedido.
5. Notas importantes Aduanas y aranceles: Los gastos de importación corren a cargo de los compradores internacionales.
Precisión de la dirección: Compruebe los datos de envío. No podemos modificar los pedidos una vez procesados.
¿Preguntas? Visite nuestro Preguntas frecuentes o póngase en contacto con support@isscasolutions.com
Valoraciones
No hay valoraciones aún.