276697 Modell-Code: DILM9-10(220V50/60HZ) Eaton DILM Schütz
$48.00
- Teil Nummer: 276697 DILM9-10(220V50/60HZ)
- Hersteller:Eaton
- Verfügbarkeit: vorrätig
- Geschätzte Vorlaufzeit: Gewöhnlich versandfertig in 1-5 Arbeitstagen
- Zustand: Brandneu
- Garantie :12 Monate
Allgemeine Spezifikationen
Produktname | Eaton Moeller® series DILM contactor |
Katalognummer | 276697 |
Modell-Code | DILM9-10(220V50/60HZ) |
EAN | 4015082766979 |
Produkt Länge/Tiefe | 75 mm |
Produkthöhe | 68 mm |
Produkt Breite | 45 mm |
Produkt Gewicht | 0.24 kg |
Zertifizierungen | IEC/EN 60947 IEC/EN 60947-4-1 UL File No.: E29096 UL Category Control No.: NLDX UL CSA CSA File No.: 012528 VDE 0660 CSA-C22.2 No. 60947-4-1-14 CSA Class No.: 2411-03, 3211-04 CE UL 60947-4-1 |
Catalog Notes | Contacts according to EN 50012 |
Features & Functions
Number of poles | Three-pole |
General
Application | Contactors for Motors |
Frame size | FS1 |
Lifespan, mechanical | 7,000,000 Operations (Coil 50/60 Hz) 10,000,000 Operations (AC operated) |
Operating frequency | 9000 mechanical Operations/h (AC operated) |
Überspannungskategorie | III |
Grad der Verschmutzung | 3 |
Produktkategorie | Contactors |
Schutz | Finger- und handrückensicher, Schutz gegen direktes Berühren bei Betätigung von vorne (EN 50274) |
Bemessungs-Stoßspannungsfestigkeit (Uimp) | 8000 V AC |
Resistance per pole | 2.5 mΩ |
Suitable for | Also motors with efficiency class IE3 |
Utilization category | AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
Spannungstyp | AC |
Ambient conditions, mechanical
Schockfestigkeit | 3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms |
Climatic environmental conditions
Betriebsumgebungstemperatur - min | -25 °C |
Betriebsumgebungstemperatur - max. | 60 °C |
Betriebsumgebungstemperatur (geschlossen) - min | 25 °C |
Betriebsumgebungstemperatur (geschlossen) - max. | 40 °C |
Umgebungstemperatur bei der Lagerung - min | 40 °C |
Umgebungstemperatur bei der Lagerung - max. | 80 °C |
Klimasicherungen | Feuchte Wärme, zyklisch, nach IEC 60068-2-30 Feuchte Wärme, konstant, nach IEC 60068-2-78 |
Electro Magnetic Compatibility
Emitted interference | According to EN 60947-1 |
Interference immunity | According to EN 60947-1 |
Terminal capacities
Terminal capacity (flexible with ferrule) | 2 x (0.75 – 2,5) mm² 1 x (0.75 – 2.5) mm² 2 x (0.75 – 2.5) mm² |
Terminal capacity (solid) | 2 x (0.75 – 2.5) mm² 1 x (0.75 – 4) mm² |
Terminal capacity (solid/stranded AWG) | Single 18 – 10, double 18 – 14 |
Stripping length (main cable) | 10 mm |
Stripping length (control circuit cable) | 10 mm |
Größe der Schraube | M3.5, Klemmschraube |
Größe des Schraubendrehers | 2, Klemmschraube, Kreuzschlitzschraubendreher 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver |
Anzugsdrehmoment | 1,2 Nm, Schraubklemmen |
Electrical Rating
Rated breaking capacity at 220/230 V | 90 A |
Rated breaking capacity at 380/400 V | 90 A |
Rated breaking capacity at 500 V | 70 A |
Rated breaking capacity at 660/690 V | 50 A |
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 22 A |
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 9 A |
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 9 A |
Rated operational current (Ie) at AC-3, 440 V | 9 A |
Rated operational current (Ie) at AC-3, 500 V | 7 A |
Rated operational current (Ie) at AC-3, 660 V, 690 V | 5 A |
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V | 6 A |
Rated operational current (Ie) at AC-4, 400 V | 6 A |
Rated operational current (Ie) at AC-4, 500 V | 5 A |
Rated operational current (Ie) at AC-4, 660 V, 690 V | 4.5 A |
Rated operational current (Ie) at DC-1, 60 V | 20 A |
Rated operational current (Ie) at DC-1, 110 V | 20 A |
Rated operational current (Ie) at DC-1, 220 V | 15 A |
Bemessungsisolationsspannung (Ui) | 690 V |
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 22 A |
Rated operational power at AC-3, 240 V, 50 Hz | 3 kW |
Rated operational power at AC-3, 380/400 V, 50 Hz | 4 kW |
Rated operational power at AC-3, 415 V, 50 Hz | 5.5 kW |
Rated operational power at AC-4, 220/230 V, 50 Hz | 1.5 kW |
Rated operational power at AC-4, 240 V, 50 Hz | 1.6 kW |
Rated operational power at AC-4, 415 V, 50 Hz | 2.8 kW |
Rated operational power at AC-4, 440 V, 50 Hz | 3 kW |
Rated operational power at AC-4, 500 V, 50 Hz | 2.8 kW |
Rated operational power at AC-4, 660/690 V, 50 Hz | 3.6 kW |
Rated operational voltage (Ue) at AC – max | 690 V |
Short-circuit rating
Short-circuit current rating (basic rating) | 5 kA, SCCR (UL/CSA) 45 A, max. Fuse, SCCR (UL/CSA) 60 A, max. CB, SCCR (UL/CSA) |
Short-circuit current rating (high fault at 480 V) | 16 A, max. CB, SCCR (UL/CSA) 30/100 kA, Fuse, SCCR (UL/CSA) 65 kA, CB, SCCR (UL/CSA) 25 A, Class RK5/ 20 A Class J, max. Fuse, SCCR (UL/CSA) |
Short-circuit current rating (high fault at 600 V) | 25 A, Class RK5/20 A, Class J, max. Fuse, SCCR (UL/CSA) 30/100 kA, Fuse, SCCR (UL/CSA) |
Short-circuit protection rating (type 1 coordination) at 400 V | 35 A gG/gL |
Short-circuit protection rating (type 1 coordination) at 690 V | 20 A gG/gL |
Short-circuit protection rating (type 2 coordination) at 400 V | 20 A gG/gL |
Short-circuit protection rating (type 2 coordination) at 690 V | 16 A gG/gL |
Conventional thermal current
Conventional thermal current Ith (1-pole, enclosed) | 45 A |
Conventional thermal current Ith (3-pole, enclosed) | 18 A |
Conventional thermal current Ith at 55°C (3-pole, open) | 21 A |
Conventional thermal current Ith of main contacts (1-pole, open) | 50 A |
Switching capacity
Switching capacity (main contacts, general use) | 20 A, Maximum motor rating (UL/CSA) |
Switching capacity (auxiliary contacts, general use) | 1 A, 250 V DC, (UL/CSA) 10 A, 600 V AC, (UL/CSA) |
Switching capacity (auxiliary contacts, pilot duty) | A600, AC operated (UL/CSA) P300, DC operated (UL/CSA) |
Switching time
Arcing time | 10 ms |
Switching time (AC operated, make contacts, closing delay) – min | 15 ms |
Switching time (AC operated, make contacts, closing delay) – max | 21 ms |
Switching time (AC operated, make contacts, opening delay) – min | 9 ms |
Switching time (AC operated, make contacts, opening delay) – max | 18 ms |
Magnet system
Drop-out voltage | AC operated: 0.6 – 0.3 x UC, AC operated |
Duty factor | 100 % |
Pick-up-Spannung | 0.8 – 1.1 V AC x Uc |
Power consumption, pick-up, 50 Hz | 25 VA, Dual-frequency coil in a cold state and 1.0 x Us 27 VA, Dual-frequency coil in a cold state and 1.0 x Us |
Power consumption, pick-up, 60 Hz | 25 VA, Dual-frequency coil in a cold state and 1.0 x Us 27 VA, Dual-frequency coil in a cold state and 1.0 x Us |
Power consumption, sealing, 50 Hz | 1.2 W, Dual-frequency coil in a cold state and 1.0 x Us 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us |
Power consumption, sealing, 60 Hz | 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us 1.2 W, Dual-frequency coil in a cold state and 1.0 x Us 4.2 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz 3.3 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz |
Nennsteuerspannung (Us) bei AC, 50 Hz - min | 220 V |
Nennsteuerspannung (Us) bei AC, 50 Hz - max | 220 V |
Nennsteuerspannung (Us) bei AC, 60 Hz - min | 220 V |
Nennsteuerspannung (Us) bei AC, 60 Hz - max | 220 V |
Nennsteuerspannung (Us) bei DC - min | 0 V |
Nennsteuerspannung (Us) bei DC - max | 0 V |
Motor Rating
Assigned motor power at 115/120 V, 60 Hz, 1-phase | 0.5 HP |
Assigned motor power at 200/208 V, 60 Hz, 3-phase | 3 HP |
Assigned motor power at 230/240 V, 60 Hz, 1-phase | 1.5 HP |
Assigned motor power at 230/240 V, 60 Hz, 3-phase | 3 HP |
Assigned motor power at 460/480 V, 60 Hz, 3-phase | 5 HP |
Assigned motor power at 575/600 V, 60 Hz, 3-phase | 7.5 HP |
Communication
Connection to SmartWire-DT | Nein |
Contacts
Anzahl der Kontakte (Schließer) | 1 |
Number of auxiliary contacts (normally closed contacts) | 0 |
Number of auxiliary contacts (normally open contacts) | 1 |
Sicherheit
Sichere Isolierung | 400 V AC, Between coil and contacts, According to EN 61140 400 V AC, Between the contacts, According to EN 61140 |
Special purpose ratings
Special purpose rating of ballast electrical discharge lamps | 18 A (480V 60Hz 3phase, 277V 60Hz 1phase) 18 A (600V 60Hz 3phase, 347V 60Hz 1phase) |
Special purpose rating of definite purpose rating | 54 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 9 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) |
Special purpose rating of elevator control | 6.1 A, 600 V 60 Hz 3-ph, (UL/CSA) 2 HP, 200 V 60 Hz 3-ph, (UL/CSA) 4.8 A, 480 V 60 Hz 3-ph, (UL/CSA) 5 HP, 600 V 60 Hz 3-ph, (UL/CSA) 2 HP, 240 V 60 Hz 3-ph, (UL/CSA) 7.8 A, 200 V 60 Hz 3-ph, (UL/CSA) 6.8 A, 240 V 60 Hz 3-ph, (UL/CSA) 3 HP, 480 V 60 Hz 3-ph, (UL/CSA) |
Special purpose rating of refrigeration control (CSA only) | 10 A, FLA 480 V 60 Hz 3phase; (CSA) 60 A, LRA 480 V 60 Hz 3phase; (CSA) 60 A, LRA 600 V 60 Hz 3phase; (CSA) 10 A, FLA 600 V 60 Hz 3phase; (CSA) |
Special purpose rating of resistance air heating | 18 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 18 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) |
Special purpose rating of tungsten incandescent lamps | 14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) 14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) |
Design verification
Geräte-Wärmeabgabe, stromabhängig Pvid | 0 W |
Wärmeabgabekapazität Pdiss | 0 W |
Nennbetriebsstrom bei spezifizierter Wärmeableitung (In) | 9 A |
10.2.2 Corrosion resistance | Meets the product standard’s requirements. |
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard’s requirements. |
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard’s requirements. |
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard’s requirements. |
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard’s requirements. |
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
10.2.7 Inscriptions | Meets the product standard’s requirements. |
10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard’s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder’s responsibility. |
10.8 Connections for external conductors | Is the panel builder’s responsibility. |
10.9.2 Power-frequency electric strength | Is the panel builder’s responsibility. |
10.9.3 Impulse withstand voltage | Is the panel builder’s responsibility. |
10.9.4 Testing of enclosures made of insulating material | Is the panel builder’s responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Gewicht | 1 kg |
---|
Du musst angemeldet sein, um eine Bewertung abgeben zu können.


1. Auftragsabwicklung: Bestellungen werden innerhalb von 1-2 Werktagen nach Zahlungsbestätigung bearbeitet. Wochenenden und Feiertage sind von den Bearbeitungszeiten ausgenommen.
2. Versandoptionen und -fristen :
a. Standardversand: 3-7 Werktage (variiert je nach Zielort).
b. Eilversand: 2-3 Werktage (es fallen zusätzliche Gebühren an).
c.Internationaler Versand: 7-15 Arbeitstage (der Zoll kann die Lieferung beeinträchtigen).
Anmerkungen:
Für vorrätige Artikel versenden wir innerhalb von 5 Werktagen nach Zahlungseingang.
Bei Produkten, die nicht auf Lager sind, oder bei Sonderanfertigungen werden die Fristen nach der Bestellung per E-Mail bestätigt.
3. Verfolgung Ihrer Bestellung: Sie erhalten eine Tracking-Nummer per E-Mail, sobald Ihre Bestellung versandt wird. Nutzen Sie unser Auftragsstatus-Portal, um Echtzeit-Updates zu erhalten.
4. Probleme bei der Zustellung?
Fehlgeschlagene Lieferungen: Wenden Sie sich zunächst an Ihren örtlichen Spediteur und dann an uns.
Falsche/fehlende Artikel? Senden Sie uns innerhalb von 7 Tagen nach der Lieferung eine E-Mail mit den Bestelldaten.
5. Wichtige Hinweise Zölle und Abgaben: Internationale Käufer sind für alle Einfuhrgebühren verantwortlich.
Korrekte Adresse: Überprüfen Sie Ihre Versanddaten - wir können einmal bearbeitete Bestellungen nicht mehr ändern!
Noch Fragen? Besuchen Sie unser FAQs oder kontaktieren: support@isscasolutions.com
Bewertungen
Es gibt noch keine Bewertungen.