Eaton 277011 DILM17-10(220V50/60HZ) DILM Contactor, 220 V ac, 230 V dc Coil, 3-Pole, 3.5 kW, 1NC

$95.00

  • Teil Nummer: 277011 DILM17-10(220V50/60HZ)
  • Hersteller:Eaton
  • Verfügbarkeit: vorrätig
  • Geschätzte Vorlaufzeit: Gewöhnlich versandfertig in 1-5 Arbeitstagen
  • Zustand: Brandneu
  • Garantie :12 Monate

datasheet 277011 DILM17-10(220V50/60HZ)

Artikelnummer: 277011 DILM17-10(220V50/60HZ) Kategorien: , Schlagwort:
Beschreibung

General Specifications

Produktname
Eaton Moeller® series DILM contactor
Katalognummer
277011
EAN
4015082770112
Produkt Länge/Tiefe
97 mm
Produkthöhe
85 mm
Produkt Breite
45 mm
Produkt Gewicht
0.428 kg
Zertifizierungen
UL File No.: E29096
CSA Class No.: 2411-03, 3211-04
UL
CSA
VDE 0660
CSA File No.: 012528
IEC/EN 60947-4-1
CSA-C22.2 No. 60947-4-1-14
CE
IEC/EN 60947
UL 60947-4-1
UL Category Control No.: NLDX
Catalog Notes
Contacts according to EN 50012
Modell-Code
DILM17-10(220V50/60HZ)

Produktspezifikationen

Electrical connection type for auxiliary- and control-current circuit
Schraubverbindung
Number of poles
Three-pole
Nennspannung
220 V
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard’s requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard’s requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard’s requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard’s requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard’s requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard’s requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard’s requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder’s responsibility.
10.8 Connections for external conductors
Is the panel builder’s responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder’s responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder’s responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder’s responsibility.
Frequency rating
50-60 Hz
Operating frequency
5000 mechanical Operations/h (AC operated)
Grad der Verschmutzung
3
Klimasicherungen
Feuchte Wärme, konstant, nach IEC 60068-2-78
Feuchte Wärme, zyklisch, nach IEC 60068-2-30
Connection to SmartWire-DT
No
Bemessungs-Stoßspannungsfestigkeit (Uimp)
8000 V AC
Utilization category
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Connection
Screw terminals
Frame size
FS2
Betriebsumgebungstemperatur - max.
60 °C
Betriebsumgebungstemperatur - min
-25 °C
Betriebsumgebungstemperatur (geschlossen) - max.
40 °C
Betriebsumgebungstemperatur (geschlossen) - min
25 °C
Umgebungstemperatur bei der Lagerung - max.
80 °C
Umgebungstemperatur bei der Lagerung - min
40 °C
Assigned motor power at 115/120 V, 60 Hz, 1-phase
2 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase
5 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase
3 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase
5 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase
10 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase
15 HP
Conventional thermal current Ith (1-pole, enclosed)
80 A
Conventional thermal current Ith (3-pole, enclosed)
32 A
Conventional thermal current Ith at 55°C (3-pole, open)
37 A
Conventional thermal current Ith of main contacts (1-pole, open)
88 A
Geräte-Wärmeabgabe, stromabhängig Pvid
2.1 W
Wärmeabgabekapazität Pdiss
0 W
Wärmeabgabe pro Pol, stromabhängig Pvid
0.7 W
Application
Contactors for Motors
Produktkategorie
Contactors
Schutz
Finger- und handrückensicher, Schutz gegen direktes Berühren bei Betätigung von vorne (EN 50274)
Arcing time
10 ms
Electrical connection type of main circuit
Schraubverbindung
Größe des Schraubendrehers
2, Klemmschraube, Kreuzschlitzschraubendreher
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Spannungstyp
AC
Grad des Schutzes
IP00
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
1
Number of contacts (normally closed) as main contact
0
Anzahl der Kontakte (Schließer)
1
Number of main contacts (normally open contact)
3
Rated breaking capacity at 220/230 V
170 A
Rated breaking capacity at 380/400 V
170 A
Rated breaking capacity at 500 V
170 A
Rated breaking capacity at 660/690 V
120 A
Nennsteuerspannung (Us) bei AC, 50 Hz - max
220 V
Nennsteuerspannung (Us) bei AC, 50 Hz - min
220 V
Nennsteuerspannung (Us) bei AC, 60 Hz - max
220 V
Nennsteuerspannung (Us) bei AC, 60 Hz - min
220 V
Contact configuration
1 NO
Drop-out voltage
AC operated: 0.6 – 0.3 x UC, AC operated
Überspannungskategorie
III
Duty factor
100 %
Emitted interference
According to EN 60947-1
Interference immunity
According to EN 60947-1
Lifespan, mechanical
10,000,000 Operations (AC operated)
7,000,000 Operations (Coil 50/60 Hz)
Pick-up-Spannung
0.8 – 1.1 V AC x Uc
Power consumption, pick-up, 50 Hz
58 VA, Dual-frequency coil in a cold state and 1.0 x Us
62 VA, Dual-frequency coil in a cold state and 1.0 x Us
Sichere Isolierung
440 V AC, Between the contacts, According to EN 61140
440 V AC, Between coil and contacts, According to EN 61140
Power consumption, pick-up, 60 Hz
62 VA, Dual-frequency coil in a cold state and 1.0 x Us
58 VA, Dual-frequency coil in a cold state and 1.0 x Us
Größe der Schraube
M5, Terminal screw, Main cables
M3.5, Terminal screw, Control circuit cables
Power consumption, sealing, 50 Hz
2.1 W, Dual-frequency coil in a cold state and 1.0 x Us
Power consumption, sealing, 60 Hz
2.1 W, Dual-frequency coil in a cold state and 1.0 x Us
6.5 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
9.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Terminal capacity (stranded)
1 x 16 mm², Main cables
Switching capacity (auxiliary contacts, general use)
10 A, 600 V AC, (UL/CSA)
1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)
P300, DC operated (UL/CSA)
A600, AC operated (UL/CSA)
Terminal capacity (flexible with ferrule)
2 x (0.75 – 10) mm², Main cables
2 x (0.75 – 2.5) mm², Control circuit cables
1 x (0.75 – 16) mm², Main cables
1 x (0.75 – 2.5) mm², Control circuit cables
Schockfestigkeit
5.3 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
6.9 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
3.5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Terminal capacity (solid)
2 x (0.75 – 10) mm², Main cables
1 x (0.75 – 16) mm², Main cables
1 x (0.75 – 4) mm², Control circuit cables
2 x (0.75 – 2.5) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)
18 – 14, Control circuit cables
Single 18 – 6, double 18 – 8, Main cables
Switching capacity (main contacts, general use)
40 A, Maximum motor rating (UL/CSA)
Stromverbrauch
7.5 kW
Anzugsdrehmoment
3.2 Nm, Screw terminals, Main cables
1.2 Nm, Screw terminals, Control circuit cables
Nennsteuerspannung (Us) bei DC - max
0 V
Nennsteuerspannung (Us) bei DC - min
0 V
Bemessungsisolationsspannung (Ui)
690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)
238 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
40 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
18 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
18 A
Rated operational current (Ie) at AC-3, 440 V
18 A
Rated operational current (Ie) at AC-3, 500 V
18 A
Rated operational current (Ie) at AC-3, 660 V, 690 V
12 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
10 A
Rated operational current (Ie) at AC-4, 400 V
10 A
Rated operational current (Ie) at AC-4, 440 V
10 A
Rated operational current (Ie) at AC-4, 500 V
10 A
Rated operational current (Ie) at AC-4, 660 V, 690 V
8 A
Rated operational current (Ie) at DC-1, 110 V
35 A
Rated operational current (Ie) at DC-1, 220 V
35 A
Rated operational current (Ie) at DC-1, 60 V
35 A
Nennbetriebsstrom bei spezifizierter Wärmeableitung (In)
18 A
Rated operational power at AC-3, 240 V, 50 Hz
5.5 kW
Rated operational power at AC-3, 380/400 V, 50 Hz
7.5 kW
Rated operational power at AC-3, 415 V, 50 Hz
10 kW
Rated operational power at AC-4, 220/230 V, 50 Hz
2.5 kW
Rated operational power at AC-4, 240 V, 50 Hz
3 kW
Rated operational power at AC-4, 380/400 V, 50 Hz
4.5 kW
Rated operational power at AC-4, 415 V, 50 Hz
5 kW
Rated operational power at AC-4, 440 V, 50 Hz
5.5 kW
Rated operational power at AC-4, 500 V, 50 Hz
6 kW
Rated operational power at AC-4, 660/690 V, 50 Hz
6.5 kW
Rated operational power (NEMA)
7.4 kW
Rated operational voltage (Ue) at AC – max
690 V
Resistance per pole
2.7 mΩ
Statische Wärmeabgabe, nicht stromabhängig Pvs
2.1 W
Stripping length (control circuit cable)
10 mm
Stripping length (main cable)
10 mm
Switching time (AC operated, make contacts, closing delay) – max
22 ms
Switching time (AC operated, make contacts, closing delay) – min
16 ms
Switching time (AC operated, make contacts, opening delay) – max
14 ms
Switching time (AC operated, make contacts, opening delay) – min
8 ms
Short-circuit current rating (basic rating)
125 A, max. CB, SCCR (UL/CSA)
5 kA, SCCR (UL/CSA)
125 A, max. Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)
125/70 A, Class J, max. Fuse, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
10/65 kA, CB, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)
10/100 kA, Fuse, SCCR (UL/CSA)
125/70 A, Class J, max. Fuse, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
10/22 kA, CB, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V
63 A gG/gL
Suitable for
Also motors with efficiency class IE3
Short-circuit protection rating (type 1 coordination) at 690 V
50 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V
35 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V
35 A gG/gL
Special purpose rating of ballast electrical discharge lamps
40 A (600V 60Hz 3phase, 347V 60Hz 1phase)
40 A (480V 60Hz 3phase, 277V 60Hz 1phase)
Special purpose rating of definite purpose rating
108 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
18 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Special purpose rating of elevator control
11 A, 480 V 60 Hz 3-ph, (UL/CSA)
11 A, 600 V 60 Hz 3-ph, (UL/CSA)
11 A, 200 V 60 Hz 3-ph, (UL/CSA)
3 HP, 200 V 60 Hz 3-ph, (UL/CSA)
9.6 A, 240 V 60 Hz 3-ph, (UL/CSA)
3 HP, 240 V 60 Hz 3-ph, (UL/CSA)
7.5 HP, 480 V 60 Hz 3-ph, (UL/CSA)
10 HP, 600 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)
180 A, LRA 600 V 60 Hz 3phase; (CSA)
40 A, FLA 480 V 60 Hz 3phase; (CSA)
30 A, FLA 600 V 60 Hz 3phase; (CSA)
240 A, LRA 480 V 60 Hz 3phase; (CSA)
Special purpose rating of resistance air heating
40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
40 A, 600 V 60 Hz 3p
Zusätzliche Informationen
Gewicht 1 kg
Größe 30 × 15 × 15 cm
Bewertungen (0)

Bewertungen

Es gibt noch keine Bewertungen.

Schreibe die erste Bewertung für „Eaton 277011 DILM17-10(220V50/60HZ) DILM Contactor, 220 V ac, 230 V dc Coil, 3-Pole, 3.5 kW, 1NC“
Versand & Lieferung

1. Auftragsabwicklung: Bestellungen werden innerhalb von 1-2 Werktagen nach Zahlungsbestätigung bearbeitet. Wochenenden und Feiertage sind von den Bearbeitungszeiten ausgenommen.
2. Versandoptionen und -fristen :
a. Standardversand: 3-7 Werktage (variiert je nach Zielort).
b. Eilversand: 2-3 Werktage (es fallen zusätzliche Gebühren an).
c.Internationaler Versand: 7-15 Arbeitstage (der Zoll kann die Lieferung beeinträchtigen).
Anmerkungen:
Für vorrätige Artikel versenden wir innerhalb von 5 Werktagen nach Zahlungseingang.
Bei Produkten, die nicht auf Lager sind, oder bei Sonderanfertigungen werden die Fristen nach der Bestellung per E-Mail bestätigt.
3. Verfolgung Ihrer Bestellung: Sie erhalten eine Tracking-Nummer per E-Mail, sobald Ihre Bestellung versandt wird. Nutzen Sie unser Auftragsstatus-Portal, um Echtzeit-Updates zu erhalten.
4. Probleme bei der Zustellung?
Fehlgeschlagene Lieferungen: Wenden Sie sich zunächst an Ihren örtlichen Spediteur und dann an uns.
Falsche/fehlende Artikel? Senden Sie uns innerhalb von 7 Tagen nach der Lieferung eine E-Mail mit den Bestelldaten.
5. Wichtige Hinweise Zölle und Abgaben: Internationale Käufer sind für alle Einfuhrgebühren verantwortlich.
Korrekte Adresse: Überprüfen Sie Ihre Versanddaten - wir können einmal bearbeitete Bestellungen nicht mehr ändern!

Noch Fragen? Besuchen Sie unser FAQs oder kontaktieren: support@isscasolutions.com