Eaton 277011 DILM17-10(220V50/60HZ) DILM Contactor, 220 V ac, 230 V dc Coil, 3-Pole, 3.5 kW, 1NC
$95.00
- Número de pieza: 277011 DILM17-10(220V50/60HZ)
- Fabricante:Eaton
- Disponibilidad: en stock
- Tiempo estimado de entrega: Normalmente se envía en 1-5 días laborables
- Estado: Nuevo
- Garantía :12 meses
General Specifications
Nombre del producto | Eaton Moeller® series DILM contactor |
Número de catálogo | 277011 |
EAN | 4015082770112 |
Longitud/profundidad del producto | 97 mm |
Altura del producto | 85 mm |
Anchura del producto | 45 mm |
Peso del producto | 0.428 kg |
Certificaciones | UL File No.: E29096 CSA Class No.: 2411-03, 3211-04 UL CSA VDE 0660 CSA File No.: 012528 IEC/EN 60947-4-1 CSA-C22.2 No. 60947-4-1-14 CE IEC/EN 60947 UL 60947-4-1 UL Category Control No.: NLDX |
Catalog Notes | Contacts according to EN 50012 |
Código de modelo | DILM17-10(220V50/60HZ) |
Product specifications
Electrical connection type for auxiliary- and control-current circuit | Screw connection |
Number of poles | Three-pole |
Tensión nominal | 220 V |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
10.2.2 Corrosion resistance | Meets the product standard’s requirements. |
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard’s requirements. |
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard’s requirements. |
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard’s requirements. |
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard’s requirements. |
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
10.2.7 Inscriptions | Meets the product standard’s requirements. |
10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard’s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder’s responsibility. |
10.8 Connections for external conductors | Is the panel builder’s responsibility. |
10.9.2 Power-frequency electric strength | Is the panel builder’s responsibility. |
10.9.3 Impulse withstand voltage | Is the panel builder’s responsibility. |
10.9.4 Testing of enclosures made of insulating material | Is the panel builder’s responsibility. |
Frequency rating | 50-60 Hz |
Operating frequency | 5000 mechanical Operations/h (AC operated) |
Pollution degree | 3 |
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Connection to SmartWire-DT | No |
Rated impulse withstand voltage (Uimp) | 8000 V AC |
Utilization category | AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
Connection | Terminales de tornillo |
Frame size | FS2 |
Ambient operating temperature – max | 60 °C |
Ambient operating temperature – min | -25 °C |
Ambient operating temperature (enclosed) – max | 40 °C |
Ambient operating temperature (enclosed) – min | 25 °C |
Ambient storage temperature – max | 80 °C |
Ambient storage temperature – min | 40 °C |
Assigned motor power at 115/120 V, 60 Hz, 1-phase | 2 HP |
Assigned motor power at 200/208 V, 60 Hz, 3-phase | 5 HP |
Assigned motor power at 230/240 V, 60 Hz, 1-phase | 3 HP |
Assigned motor power at 230/240 V, 60 Hz, 3-phase | 5 HP |
Assigned motor power at 460/480 V, 60 Hz, 3-phase | 10 HP |
Assigned motor power at 575/600 V, 60 Hz, 3-phase | 15 HP |
Conventional thermal current Ith (1-pole, enclosed) | 80 A |
Conventional thermal current Ith (3-pole, enclosed) | 32 A |
Conventional thermal current Ith at 55°C (3-pole, open) | 37 A |
Conventional thermal current Ith of main contacts (1-pole, open) | 88 A |
Equipment heat dissipation, current-dependent Pvid | 2.1 W |
Heat dissipation capacity Pdiss | 0 W |
Heat dissipation per pole, current-dependent Pvid | 0.7 W |
Aplicación | Contactors for Motors |
Product category | Contactors |
Protection | Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274) |
Arcing time | 10 ms |
Electrical connection type of main circuit | Screw connection |
Screwdriver size | 2, Terminal screw, Pozidriv screwdriver 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver |
Tipo de tensión | CA |
Grado de protección | IP00 |
Number of auxiliary contacts (normally closed contacts) | 0 |
Number of auxiliary contacts (normally open contacts) | 1 |
Number of contacts (normally closed) as main contact | 0 |
Number of contacts (normally open contacts) | 1 |
Number of main contacts (normally open contact) | 3 |
Rated breaking capacity at 220/230 V | 170 A |
Rated breaking capacity at 380/400 V | 170 A |
Rated breaking capacity at 500 V | 170 A |
Rated breaking capacity at 660/690 V | 120 A |
Rated control supply voltage (Us) at AC, 50 Hz – max | 220 V |
Rated control supply voltage (Us) at AC, 50 Hz – min | 220 V |
Rated control supply voltage (Us) at AC, 60 Hz – max | 220 V |
Rated control supply voltage (Us) at AC, 60 Hz – min | 220 V |
Contact configuration | 1 NO |
Drop-out voltage | AC operated: 0.6 – 0.3 x UC, AC operated |
Overvoltage category | III |
Duty factor | 100 % |
Emitted interference | According to EN 60947-1 |
Interference immunity | According to EN 60947-1 |
Lifespan, mechanical | 10,000,000 Operations (AC operated) 7,000,000 Operations (Coil 50/60 Hz) |
Pick-up voltage | 0.8 – 1.1 V AC x Uc |
Power consumption, pick-up, 50 Hz | 58 VA, Dual-frequency coil in a cold state and 1.0 x Us 62 VA, Dual-frequency coil in a cold state and 1.0 x Us |
Safe isolation | 440 V AC, Between the contacts, According to EN 61140 440 V AC, Between coil and contacts, According to EN 61140 |
Power consumption, pick-up, 60 Hz | 62 VA, Dual-frequency coil in a cold state and 1.0 x Us 58 VA, Dual-frequency coil in a cold state and 1.0 x Us |
Screw size | M5, Terminal screw, Main cables M3.5, Terminal screw, Control circuit cables |
Power consumption, sealing, 50 Hz | 2.1 W, Dual-frequency coil in a cold state and 1.0 x Us |
Power consumption, sealing, 60 Hz | 2.1 W, Dual-frequency coil in a cold state and 1.0 x Us 6.5 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz 9.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz |
Terminal capacity (stranded) | 1 x 16 mm², Main cables |
Switching capacity (auxiliary contacts, general use) | 10 A, 600 V AC, (UL/CSA) 1 A, 250 V DC, (UL/CSA) |
Switching capacity (auxiliary contacts, pilot duty) | P300, DC operated (UL/CSA) A600, AC operated (UL/CSA) |
Terminal capacity (flexible with ferrule) | 2 x (0.75 – 10) mm², Main cables 2 x (0.75 – 2.5) mm², Control circuit cables 1 x (0.75 – 16) mm², Main cables 1 x (0.75 – 2.5) mm², Control circuit cables |
Shock resistance | 5.3 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 6.9 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 3.5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
Terminal capacity (solid) | 2 x (0.75 – 10) mm², Main cables 1 x (0.75 – 16) mm², Main cables 1 x (0.75 – 4) mm², Control circuit cables 2 x (0.75 – 2.5) mm², Control circuit cables |
Terminal capacity (solid/stranded AWG) | 18 – 14, Control circuit cables Single 18 – 6, double 18 – 8, Main cables |
Switching capacity (main contacts, general use) | 40 A, Maximum motor rating (UL/CSA) |
Consumo de energía | 7.5 kW |
Tightening torque | 3.2 Nm, Screw terminals, Main cables 1.2 Nm, Screw terminals, Control circuit cables |
Rated control supply voltage (Us) at DC – max | 0 V |
Rated control supply voltage (Us) at DC – min | 0 V |
Rated insulation voltage (Ui) | 690 V |
Rated making capacity up to 690 V (cos phi to IEC/EN 60947) | 238 A |
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 40 A |
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 18 A |
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 18 A |
Rated operational current (Ie) at AC-3, 440 V | 18 A |
Rated operational current (Ie) at AC-3, 500 V | 18 A |
Rated operational current (Ie) at AC-3, 660 V, 690 V | 12 A |
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V | 10 A |
Rated operational current (Ie) at AC-4, 400 V | 10 A |
Rated operational current (Ie) at AC-4, 440 V | 10 A |
Rated operational current (Ie) at AC-4, 500 V | 10 A |
Rated operational current (Ie) at AC-4, 660 V, 690 V | 8 A |
Rated operational current (Ie) at DC-1, 110 V | 35 A |
Rated operational current (Ie) at DC-1, 220 V | 35 A |
Rated operational current (Ie) at DC-1, 60 V | 35 A |
Rated operational current for specified heat dissipation (In) | 18 A |
Rated operational power at AC-3, 240 V, 50 Hz | 5.5 kW |
Rated operational power at AC-3, 380/400 V, 50 Hz | 7.5 kW |
Rated operational power at AC-3, 415 V, 50 Hz | 10 kW |
Rated operational power at AC-4, 220/230 V, 50 Hz | 2.5 kW |
Rated operational power at AC-4, 240 V, 50 Hz | 3 kW |
Rated operational power at AC-4, 380/400 V, 50 Hz | 4.5 kW |
Rated operational power at AC-4, 415 V, 50 Hz | 5 kW |
Rated operational power at AC-4, 440 V, 50 Hz | 5.5 kW |
Rated operational power at AC-4, 500 V, 50 Hz | 6 kW |
Rated operational power at AC-4, 660/690 V, 50 Hz | 6.5 kW |
Rated operational power (NEMA) | 7.4 kW |
Rated operational voltage (Ue) at AC – max | 690 V |
Resistance per pole | 2.7 mΩ |
Static heat dissipation, non-current-dependent Pvs | 2.1 W |
Stripping length (control circuit cable) | 10 mm |
Stripping length (main cable) | 10 mm |
Switching time (AC operated, make contacts, closing delay) – max | 22 ms |
Switching time (AC operated, make contacts, closing delay) – min | 16 ms |
Switching time (AC operated, make contacts, opening delay) – max | 14 ms |
Switching time (AC operated, make contacts, opening delay) – min | 8 ms |
Short-circuit current rating (basic rating) | 125 A, max. CB, SCCR (UL/CSA) 5 kA, SCCR (UL/CSA) 125 A, max. Fuse, SCCR (UL/CSA) |
Short-circuit current rating (high fault at 480 V) | 125/70 A, Class J, max. Fuse, SCCR (UL/CSA) 50/32 A, max. CB, SCCR (UL/CSA) 10/65 kA, CB, SCCR (UL/CSA) 10/100 kA, Fuse, SCCR (UL/CSA) |
Short-circuit current rating (high fault at 600 V) | 10/100 kA, Fuse, SCCR (UL/CSA) 125/70 A, Class J, max. Fuse, SCCR (UL/CSA) 50/32 A, max. CB, SCCR (UL/CSA) 10/22 kA, CB, SCCR (UL/CSA) |
Short-circuit protection rating (type 1 coordination) at 400 V | 63 A gG/gL |
Suitable for | Also motors with efficiency class IE3 |
Short-circuit protection rating (type 1 coordination) at 690 V | 50 A gG/gL |
Short-circuit protection rating (type 2 coordination) at 400 V | 35 A gG/gL |
Short-circuit protection rating (type 2 coordination) at 690 V | 35 A gG/gL |
Special purpose rating of ballast electrical discharge lamps | 40 A (600V 60Hz 3phase, 347V 60Hz 1phase) 40 A (480V 60Hz 3phase, 277V 60Hz 1phase) |
Special purpose rating of definite purpose rating | 108 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 18 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) |
Special purpose rating of elevator control | 11 A, 480 V 60 Hz 3-ph, (UL/CSA) 11 A, 600 V 60 Hz 3-ph, (UL/CSA) 11 A, 200 V 60 Hz 3-ph, (UL/CSA) 3 HP, 200 V 60 Hz 3-ph, (UL/CSA) 9.6 A, 240 V 60 Hz 3-ph, (UL/CSA) 3 HP, 240 V 60 Hz 3-ph, (UL/CSA) 7.5 HP, 480 V 60 Hz 3-ph, (UL/CSA) 10 HP, 600 V 60 Hz 3-ph, (UL/CSA) |
Special purpose rating of refrigeration control (CSA only) | 180 A, LRA 600 V 60 Hz 3phase; (CSA) 40 A, FLA 480 V 60 Hz 3phase; (CSA) 30 A, FLA 600 V 60 Hz 3phase; (CSA) 240 A, LRA 480 V 60 Hz 3phase; (CSA) |
Special purpose rating of resistance air heating | 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 40 A, 600 V 60 Hz 3p |
Peso | 1 kg |
---|---|
Dimensiones | 30 × 15 × 15 cm |
Debes acceder para publicar una valoración.


1. Tramitación de pedidos: Los pedidos se tramitan en un plazo de 1 a 2 días laborables tras la confirmación del pago. Los fines de semana y los días festivos no se tienen en cuenta.
2. Opciones de envío y plazos :
a.Envío estándar: 3-7 días laborables (varía según el destino).
b.Envío urgente: 2-3 días laborables (se aplicarán tarifas adicionales).
c.Envíos internacionales: 7-15 días laborables (las aduanas pueden afectar a la entrega).
Notas:
Para los artículos en stock, enviamos dentro de 5 días hábiles después de recibir el pago.
Los plazos de entrega de los productos fuera de stock o personalizados se confirmarán por correo electrónico tras la realización del pedido.
3. Seguimiento de su pedido: Recibirá un número de seguimiento por correo electrónico cuando se envíe su pedido. Utilice nuestro portal de estado de pedidos para comprobar las actualizaciones en tiempo real.
4. ¿Problemas de entrega?
Entregas fallidas: Contacte primero con su transportista local y después con nosotros.
¿Se ha equivocado o le faltan artículos? Envíenos un correo electrónico dentro de los 7 días de la entrega con los detalles del pedido.
5. Notas importantes Aduanas y aranceles: Los gastos de importación corren a cargo de los compradores internacionales.
Precisión de la dirección: Compruebe los datos de envío. No podemos modificar los pedidos una vez procesados.
¿Preguntas? Visite nuestro Preguntas frecuentes o póngase en contacto con support@isscasolutions.com
Valoraciones
No hay valoraciones aún.