Eaton Moeller 276426 Código de modelo: DILA-XHI22 Módulo de contacto auxiliar DILA
$32.00
- Número de pieza: 276426 DILA-XHI22
- Fabricante:Eaton Moeller
- Disponibilidad: En stock
- Tiempo estimado de entrega: 1-2 semanas
- Estado: Nuevo
- Garantía :12 meses
Descripción
Especificaciones generales
Nombre del producto |
Eaton Moeller® series DILA Accessory Auxiliary contact module
|
Número de catálogo |
276426
|
Código de modelo |
DILA-XHI22
|
UPC |
782116354597
|
EAN |
4015082764265
|
Longitud/profundidad del producto |
45 mm
|
Altura del producto |
38 mm
|
Anchura del producto |
36 mm
|
Peso del producto |
0.049 kg
|
Certificaciones |
IEC/EN 60947-4-1
CSA-C22.2 No. 14-05 UL Category Control No.: NKCR CSA UL 508 VDE 0660 CSA Class No.: 3211-03 CE IEC/EN 60947 CSA File No.: 012528 UL UL File No.: E29184 |
Global Catalog |
276426
|
Product specifications
Type |
Front mounting auxiliary contact
|
Características |
Interlocked opposing contacts within an auxiliary contact module (according to IEC 60947-5-1 Annex L)
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard’s requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard’s requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard’s requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard’s requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard’s requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard’s requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard’s requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder’s responsibility.
|
10.8 Connections for external conductors |
Is the panel builder’s responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder’s responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder’s responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder’s responsibility.
|
Electric connection type |
Screw connection
|
Fitted with: |
Interlocked opposing contacts
Switching elements according to EN 50005 |
Operating frequency |
9000 Operations/h
|
Pollution degree |
3
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
Ambient operating temperature – max |
60 °C
|
Ambient operating temperature – min |
-25 °C
|
Ambient operating temperature (enclosed) – max |
40 °C
|
Ambient operating temperature (enclosed) – min |
-25 °C
|
Ambient storage temperature – max |
80 °C
|
Ambient storage temperature – min |
-40 °C
|
Conventional thermal current Ith at 60°C (3-pole, open) |
16 A
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0.16 W
|
Number of contacts (change-over contacts) |
0
|
Number of contacts (normally closed contacts) |
2
|
Number of contacts (normally open contacts) |
2
|
Number of switches (fault signal) |
0
|
Rated impulse withstand voltage (Uimp) |
6000 V AC
|
Screwdriver size |
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
2, Terminal screw, Pozidriv screwdriver |
Método de montaje |
Front fastening
|
Conexión |
Terminales de tornillo
|
Overvoltage category |
III
|
Control circuit reliability |
λ < 5 x 10-7 (1 failure at 2,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA)
λ < 5 x 1/10⁷ (1 failure at 2,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA) |
Grado de protección |
IP20
|
Code number |
62E in combination with DILA(C)-40
44 in combination with DILA(C)-22 53 in combination with DILA(C)-31 |
Model |
Top mounting
|
Lamp holder |
Ninguno
|
Functions |
For standard applications
|
Safe isolation |
400 V AC, Between auxiliary contacts, According to EN 61140
400 V AC, Between coil and auxiliary contacts, According to EN 61140 |
Rated operational current (Ie) |
10 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series)
6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series) 1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series) 0.5 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series) 1 A at 60 V, DC L/R ≤ 50 ms (with 3 contacts in series) 5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series) 2.5 A at 24 V, DC L/R ≤ 50 ms (with 3 contacts in series) 10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series) 0.25 A at 220 V, DC L/R ≤ 50 ms (with 3 contacts in series) 3 A at 110 V, DC L/R ≤ 15 ms (with 1 contact in series) 6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series) |
Screw size |
M3.5, Terminal screw
|
Lifespan, electrical |
1,300,000 Operations (at 230 V, AC-15, 3 A)
|
Switching capacity (auxiliary contacts, general use) |
1 A, 250 V DC, (UL/CSA)
10 A, 600 V AC, (UL/CSA) |
Switching capacity (auxiliary contacts, pilot duty) |
P300, DC operated (UL/CSA)
A600, AC operated (UL/CSA) |
Lifespan, mechanical |
10,000,000 Operations (DC operated)
10,000,000 Operations (AC operated) |
Static heat dissipation, non-current-dependent Pvs |
0 W
|
Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
Number of poles |
Four-pole
|
Short-circuit protection rating without welding |
10 A gG/gL, 500 V, Max. Fuse, Contacts
|
Short-circuit protection rating |
Max. 10 A gG/gL, Fuse, Without welding, Auxiliary contacts
|
Rated insulation voltage (Ui) |
690 V
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
4 A
|
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V |
4 A
|
Rated operational current (Ie) at AC-15, 500 V |
1.5 A
|
Rated operational current (Ie) at DC-13, 110 V |
0.5 A
|
Rated operational current (Ie) at DC-13, 220 V, 230 V |
0.25 A
|
Rated operational current (Ie) at DC-13, 24 V |
2.5 A
|
Rated operational current (Ie) at DC-13, 60 V |
1 A
|
Rated operational current for specified heat dissipation (In) |
4 A
|
Rated operational voltage (Ue) at AC – max |
500 V
|
Terminal capacity (flexible with ferrule) |
1 x (0.75 – 2.5) mm², Screw terminals
2 x (0.75 – 2.5) mm², Screw terminals |
Terminal capacity (solid) |
2 x (0.75 – 2.5) mm², Screw terminals
1 x (0.75 – 2.5) mm², Screw terminals |
Tightening torque |
1.2 Nm, Screw terminals
|
Terminal capacity (solid/stranded AWG) |
18 – 14, Screw terminals
|
Shock resistance |
5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
Información adicional
Peso | 1 kg |
---|---|
Dimensiones | 20 × 15 × 15 cm |
Valoraciones (0)
Sé el primero en valorar “Eaton Moeller 276426 Model Code: DILA-XHI22 DILA Auxiliary Contact Module” Cancelar la respuesta
Debes acceder para publicar una valoración.
Envío y entrega


1. Tramitación de pedidos: Los pedidos se tramitan en un plazo de 1 a 2 días laborables tras la confirmación del pago. Los fines de semana y los días festivos no se tienen en cuenta.
2. Opciones de envío y plazos :
a.Envío estándar: 3-7 días laborables (varía según el destino).
b.Envío urgente: 2-3 días laborables (se aplicarán tarifas adicionales).
c.Envíos internacionales: 7-15 días laborables (las aduanas pueden afectar a la entrega).
Notas:
Para los artículos en stock, enviamos dentro de 5 días hábiles después de recibir el pago.
Los plazos de entrega de los productos fuera de stock o personalizados se confirmarán por correo electrónico tras la realización del pedido.
3. Seguimiento de su pedido: Recibirá un número de seguimiento por correo electrónico cuando se envíe su pedido. Utilice nuestro portal de estado de pedidos para comprobar las actualizaciones en tiempo real.
4. ¿Problemas de entrega?
Entregas fallidas: Contacte primero con su transportista local y después con nosotros.
¿Se ha equivocado o le faltan artículos? Envíenos un correo electrónico dentro de los 7 días de la entrega con los detalles del pedido.
5. Notas importantes Aduanas y aranceles: Los gastos de importación corren a cargo de los compradores internacionales.
Precisión de la dirección: Compruebe los datos de envío. No podemos modificar los pedidos una vez procesados.
¿Preguntas? Visite nuestro Preguntas frecuentes o póngase en contacto con support@isscasolutions.com
Valoraciones
No hay valoraciones aún.