Eaton 277011 DILM17-10(220V50/60HZ) DILM Contactor, 220 V ac, 230 V dc Coil, 3-Pole, 3.5 kW, 1NC
$95.00
- 部品番号 277011 DILM17-10(220V50/60HZ)
- メーカーイートン
- 空室状況 在庫あり
- 推定リードタイム: 通常1-5営業日で出荷
- コンディション 新品
- 保証:12ヶ月
説明
General Specifications
製品名 | Eaton Moeller® series DILM contactor |
カタログ番号 | 277011 |
イーエヌ | 4015082770112 |
製品の長さ/深さ | 97 mm |
製品高さ | 85 mm |
製品幅 | 45 mm |
製品重量 | 0.428 kg |
認証 | UL File No.: E29096 CSA Class No.: 2411-03, 3211-04 UL CSA VDE 0660 CSA File No.: 012528 IEC/EN 60947-4-1 CSA-C22.2 No. 60947-4-1-14 CE IEC/EN 60947 UL 60947-4-1 UL Category Control No.: NLDX |
Catalog Notes | Contacts according to EN 50012 |
モデルコード | DILM17-10(220V50/60HZ) |
Product specifications
Electrical connection type for auxiliary- and control-current circuit | Screw connection |
Number of poles | Three-pole |
定格電圧 | 220 V |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
10.2.2 Corrosion resistance | Meets the product standard’s requirements. |
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard’s requirements. |
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard’s requirements. |
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard’s requirements. |
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard’s requirements. |
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
10.2.7 Inscriptions | Meets the product standard’s requirements. |
10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard’s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder’s responsibility. |
10.8 Connections for external conductors | Is the panel builder’s responsibility. |
10.9.2 Power-frequency electric strength | Is the panel builder’s responsibility. |
10.9.3 Impulse withstand voltage | Is the panel builder’s responsibility. |
10.9.4 Testing of enclosures made of insulating material | Is the panel builder’s responsibility. |
Frequency rating | 50-60 Hz |
Operating frequency | 5000 mechanical Operations/h (AC operated) |
Pollution degree | 3 |
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Connection to SmartWire-DT | いいえ |
Rated impulse withstand voltage (Uimp) | 8000 V AC |
Utilization category | AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
Connection | ネジ端子 |
Frame size | FS2 |
Ambient operating temperature – max | 60 °C |
Ambient operating temperature – min | -25 °C |
Ambient operating temperature (enclosed) – max | 40 °C |
Ambient operating temperature (enclosed) – min | 25 °C |
Ambient storage temperature – max | 80 °C |
Ambient storage temperature – min | 40 °C |
Assigned motor power at 115/120 V, 60 Hz, 1-phase | 2 HP |
Assigned motor power at 200/208 V, 60 Hz, 3-phase | 5 HP |
Assigned motor power at 230/240 V, 60 Hz, 1-phase | 3 HP |
Assigned motor power at 230/240 V, 60 Hz, 3-phase | 5 HP |
Assigned motor power at 460/480 V, 60 Hz, 3-phase | 10 HP |
Assigned motor power at 575/600 V, 60 Hz, 3-phase | 15 HP |
Conventional thermal current Ith (1-pole, enclosed) | 80 A |
Conventional thermal current Ith (3-pole, enclosed) | 32 A |
Conventional thermal current Ith at 55°C (3-pole, open) | 37 A |
Conventional thermal current Ith of main contacts (1-pole, open) | 88 A |
Equipment heat dissipation, current-dependent Pvid | 2.1 W |
Heat dissipation capacity Pdiss | 0 W |
Heat dissipation per pole, current-dependent Pvid | 0.7 W |
Application | Contactors for Motors |
Product category | Contactors |
Protection | Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274) |
Arcing time | 10 ms |
Electrical connection type of main circuit | Screw connection |
Screwdriver size | 2, Terminal screw, Pozidriv screwdriver 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver |
電圧タイプ | 交流 |
Degree of protection | IP00 |
Number of auxiliary contacts (normally closed contacts) | 0 |
Number of auxiliary contacts (normally open contacts) | 1 |
Number of contacts (normally closed) as main contact | 0 |
Number of contacts (normally open contacts) | 1 |
Number of main contacts (normally open contact) | 3 |
Rated breaking capacity at 220/230 V | 170 A |
Rated breaking capacity at 380/400 V | 170 A |
Rated breaking capacity at 500 V | 170 A |
Rated breaking capacity at 660/690 V | 120 A |
Rated control supply voltage (Us) at AC, 50 Hz – max | 220 V |
Rated control supply voltage (Us) at AC, 50 Hz – min | 220 V |
Rated control supply voltage (Us) at AC, 60 Hz – max | 220 V |
Rated control supply voltage (Us) at AC, 60 Hz – min | 220 V |
Contact configuration | 1 NO |
Drop-out voltage | AC operated: 0.6 – 0.3 x UC, AC operated |
Overvoltage category | III |
Duty factor | 100 % |
Emitted interference | According to EN 60947-1 |
Interference immunity | According to EN 60947-1 |
Lifespan, mechanical | 10,000,000 Operations (AC operated) 7,000,000 Operations (Coil 50/60 Hz) |
Pick-up voltage | 0.8 – 1.1 V AC x Uc |
Power consumption, pick-up, 50 Hz | 58 VA, Dual-frequency coil in a cold state and 1.0 x Us 62 VA, Dual-frequency coil in a cold state and 1.0 x Us |
Safe isolation | 440 V AC, Between the contacts, According to EN 61140 440 V AC, Between coil and contacts, According to EN 61140 |
Power consumption, pick-up, 60 Hz | 62 VA, Dual-frequency coil in a cold state and 1.0 x Us 58 VA, Dual-frequency coil in a cold state and 1.0 x Us |
Screw size | M5, Terminal screw, Main cables M3.5, Terminal screw, Control circuit cables |
Power consumption, sealing, 50 Hz | 2.1 W, Dual-frequency coil in a cold state and 1.0 x Us |
Power consumption, sealing, 60 Hz | 2.1 W, Dual-frequency coil in a cold state and 1.0 x Us 6.5 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz 9.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz |
Terminal capacity (stranded) | 1 x 16 mm², Main cables |
Switching capacity (auxiliary contacts, general use) | 10 A, 600 V AC, (UL/CSA) 1 A, 250 V DC, (UL/CSA) |
Switching capacity (auxiliary contacts, pilot duty) | P300, DC operated (UL/CSA) A600, AC operated (UL/CSA) |
Terminal capacity (flexible with ferrule) | 2 x (0.75 – 10) mm², Main cables 2 x (0.75 – 2.5) mm², Control circuit cables 1 x (0.75 – 16) mm², Main cables 1 x (0.75 – 2.5) mm², Control circuit cables |
Shock resistance | 5.3 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 6.9 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 3.5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
Terminal capacity (solid) | 2 x (0.75 – 10) mm², Main cables 1 x (0.75 – 16) mm², Main cables 1 x (0.75 – 4) mm², Control circuit cables 2 x (0.75 – 2.5) mm², Control circuit cables |
Terminal capacity (solid/stranded AWG) | 18 – 14, Control circuit cables Single 18 – 6, double 18 – 8, Main cables |
Switching capacity (main contacts, general use) | 40 A, Maximum motor rating (UL/CSA) |
Power consumption | 7.5 kW |
Tightening torque | 3.2 Nm, Screw terminals, Main cables 1.2 Nm, Screw terminals, Control circuit cables |
Rated control supply voltage (Us) at DC – max | 0 V |
Rated control supply voltage (Us) at DC – min | 0 V |
Rated insulation voltage (Ui) | 690 V |
Rated making capacity up to 690 V (cos phi to IEC/EN 60947) | 238 A |
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 40 A |
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 18 A |
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 18 A |
Rated operational current (Ie) at AC-3, 440 V | 18 A |
Rated operational current (Ie) at AC-3, 500 V | 18 A |
Rated operational current (Ie) at AC-3, 660 V, 690 V | 12 A |
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V | 10 A |
Rated operational current (Ie) at AC-4, 400 V | 10 A |
Rated operational current (Ie) at AC-4, 440 V | 10 A |
Rated operational current (Ie) at AC-4, 500 V | 10 A |
Rated operational current (Ie) at AC-4, 660 V, 690 V | 8 A |
Rated operational current (Ie) at DC-1, 110 V | 35 A |
Rated operational current (Ie) at DC-1, 220 V | 35 A |
Rated operational current (Ie) at DC-1, 60 V | 35 A |
Rated operational current for specified heat dissipation (In) | 18 A |
Rated operational power at AC-3, 240 V, 50 Hz | 5.5 kW |
Rated operational power at AC-3, 380/400 V, 50 Hz | 7.5 kW |
Rated operational power at AC-3, 415 V, 50 Hz | 10 kW |
Rated operational power at AC-4, 220/230 V, 50 Hz | 2.5 kW |
Rated operational power at AC-4, 240 V, 50 Hz | 3 kW |
Rated operational power at AC-4, 380/400 V, 50 Hz | 4.5 kW |
Rated operational power at AC-4, 415 V, 50 Hz | 5 kW |
Rated operational power at AC-4, 440 V, 50 Hz | 5.5 kW |
Rated operational power at AC-4, 500 V, 50 Hz | 6 kW |
Rated operational power at AC-4, 660/690 V, 50 Hz | 6.5 kW |
Rated operational power (NEMA) | 7.4 kW |
Rated operational voltage (Ue) at AC – max | 690 V |
Resistance per pole | 2.7 mΩ |
Static heat dissipation, non-current-dependent Pvs | 2.1 W |
Stripping length (control circuit cable) | 10 mm |
Stripping length (main cable) | 10 mm |
Switching time (AC operated, make contacts, closing delay) – max | 22 ms |
Switching time (AC operated, make contacts, closing delay) – min | 16 ms |
Switching time (AC operated, make contacts, opening delay) – max | 14 ms |
Switching time (AC operated, make contacts, opening delay) – min | 8 ms |
Short-circuit current rating (basic rating) | 125 A, max. CB, SCCR (UL/CSA) 5 kA, SCCR (UL/CSA) 125 A, max. Fuse, SCCR (UL/CSA) |
Short-circuit current rating (high fault at 480 V) | 125/70 A, Class J, max. Fuse, SCCR (UL/CSA) 50/32 A, max. CB, SCCR (UL/CSA) 10/65 kA, CB, SCCR (UL/CSA) 10/100 kA, Fuse, SCCR (UL/CSA) |
Short-circuit current rating (high fault at 600 V) | 10/100 kA, Fuse, SCCR (UL/CSA) 125/70 A, Class J, max. Fuse, SCCR (UL/CSA) 50/32 A, max. CB, SCCR (UL/CSA) 10/22 kA, CB, SCCR (UL/CSA) |
Short-circuit protection rating (type 1 coordination) at 400 V | 63 A gG/gL |
Suitable for | Also motors with efficiency class IE3 |
Short-circuit protection rating (type 1 coordination) at 690 V | 50 A gG/gL |
Short-circuit protection rating (type 2 coordination) at 400 V | 35 A gG/gL |
Short-circuit protection rating (type 2 coordination) at 690 V | 35 A gG/gL |
Special purpose rating of ballast electrical discharge lamps | 40 A (600V 60Hz 3phase, 347V 60Hz 1phase) 40 A (480V 60Hz 3phase, 277V 60Hz 1phase) |
Special purpose rating of definite purpose rating | 108 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 18 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) |
Special purpose rating of elevator control | 11 A, 480 V 60 Hz 3-ph, (UL/CSA) 11 A, 600 V 60 Hz 3-ph, (UL/CSA) 11 A, 200 V 60 Hz 3-ph, (UL/CSA) 3 HP, 200 V 60 Hz 3-ph, (UL/CSA) 9.6 A, 240 V 60 Hz 3-ph, (UL/CSA) 3 HP, 240 V 60 Hz 3-ph, (UL/CSA) 7.5 HP, 480 V 60 Hz 3-ph, (UL/CSA) 10 HP, 600 V 60 Hz 3-ph, (UL/CSA) |
Special purpose rating of refrigeration control (CSA only) | 180 A, LRA 600 V 60 Hz 3phase; (CSA) 40 A, FLA 480 V 60 Hz 3phase; (CSA) 30 A, FLA 600 V 60 Hz 3phase; (CSA) 240 A, LRA 480 V 60 Hz 3phase; (CSA) |
Special purpose rating of resistance air heating | 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 40 A, 600 V 60 Hz 3p |
追加情報
重さ | 1 kg |
---|---|
サイズ | 30 × 15 × 15 cm |
レビュー (0)
“Eaton 277011 DILM17-10(220V50/60HZ) DILM Contactor, 220 V ac, 230 V dc Coil, 3-Pole, 3.5 kW, 1NC” の口コミを投稿します コメントをキャンセル
レビューを投稿するにはログインする必要があります。
配送


1. 注文処理: ご注文は入金確認後、1~2営業日以内に処理されます。土日祝日は除きます。
2. 配送オプションとスケジュール:
a.標準配送:3~7営業日(お届け先によって異なります。)
b.Expedited Shipping: 2-3 営業日 (追加料金がかかります)。
c.国際配送:7-15営業日(税関が配信に影響を与える可能性があります)。
注釈
在庫のある商品につきましては、ご入金確認後5営業日以内に発送いたします。
在庫切れの商品や特注品については、ご注文後にメールにて納期を確認させていただきます。
3.ご注文の追跡 ご注文の商品が発送されると、Eメールで追跡番号が届きます。ご注文状況ポータルサイトで、リアルタイムで最新情報をご確認いただけます。
4.配送の問題?
配達に失敗しました:まずはお近くの運送会社にお問い合わせください。
商品の間違い・紛失商品到着後7日以内にEメールにてご注文内容をお知らせください。
5.重要な注意事項 税関と関税: 海外からの購入者は、輸入手数料を負担する必要があります。
住所の正確さ:一度処理された注文を修正することはできません!
質問は? 私たちのウェブサイトをご覧ください。 よくある質問 または連絡先まで: support@isscasolutions.com
レビュー
レビューはまだありません。