276697 Código do modelo: DILM9-10(220V50/60HZ) Contactor DILM Eaton
$48.00
- Número da peça: 276697 DILM9-10(220V50/60HZ)
- Fabricante:Eaton
- Disponibilidade: em stock
- Tempo de espera estimado: Geralmente enviado em 1-5 dias úteis
- Estado: Novíssimo
- Garantia :12 meses
Especificações gerais
Nome do produto | Eaton Moeller® series DILM contactor |
Número de catálogo | 276697 |
Código do modelo | DILM9-10(220V50/60HZ) |
EAN | 4015082766979 |
Comprimento/profundidade do produto | 75 mm |
Altura do produto | 68 mm |
Largura do produto | 45 mm |
Peso do produto | 0.24 kg |
Certificações | IEC/EN 60947 IEC/EN 60947-4-1 UL File No.: E29096 UL Category Control No.: NLDX UL CSA CSA File No.: 012528 VDE 0660 CSA-C22.2 No. 60947-4-1-14 CSA Class No.: 2411-03, 3211-04 CE UL 60947-4-1 |
Catalog Notes | Contacts according to EN 50012 |
Features & Functions
Número de postes | Tripolar |
General
Aplicação | Contactors for Motors |
Frame size | FS1 |
Lifespan, mechanical | 7,000,000 Operations (Coil 50/60 Hz) 10,000,000 Operations (AC operated) |
Operating frequency | 9000 mechanical Operations/h (AC operated) |
Categoria de sobretensão | III |
Grau de poluição | 3 |
Product category | Contactors |
Protection | Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274) |
Tensão nominal de resistência ao impulso (Uimp) | 8000 V AC |
Resistance per pole | 2.5 mΩ |
Suitable for | Also motors with efficiency class IE3 |
Utilization category | AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
Tipo de tensão | AC |
Ambient conditions, mechanical
Shock resistance | 3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms |
Climatic environmental conditions
Temperatura ambiente de funcionamento - min | -25 °C |
Temperatura ambiente de funcionamento - máx | 60 °C |
Ambient operating temperature (enclosed) – min | 25 °C |
Ambient operating temperature (enclosed) – max | 40 °C |
Ambient storage temperature – min | 40 °C |
Ambient storage temperature – max | 80 °C |
Climatic proofing | Damp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78 |
Electro Magnetic Compatibility
Emitted interference | According to EN 60947-1 |
Interference immunity | According to EN 60947-1 |
Terminal capacities
Terminal capacity (flexible with ferrule) | 2 x (0.75 – 2,5) mm² 1 x (0.75 – 2.5) mm² 2 x (0.75 – 2.5) mm² |
Terminal capacity (solid) | 2 x (0.75 – 2.5) mm² 1 x (0.75 – 4) mm² |
Terminal capacity (solid/stranded AWG) | Single 18 – 10, double 18 – 14 |
Stripping length (main cable) | 10 mm |
Stripping length (control circuit cable) | 10 mm |
Screw size | M3.5, Terminal screw |
Screwdriver size | 2, Terminal screw, Pozidriv screwdriver 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver |
Tightening torque | 1.2 Nm, Screw terminals |
Electrical Rating
Rated breaking capacity at 220/230 V | 90 A |
Rated breaking capacity at 380/400 V | 90 A |
Rated breaking capacity at 500 V | 70 A |
Rated breaking capacity at 660/690 V | 50 A |
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 22 A |
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 9 A |
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 9 A |
Rated operational current (Ie) at AC-3, 440 V | 9 A |
Rated operational current (Ie) at AC-3, 500 V | 7 A |
Rated operational current (Ie) at AC-3, 660 V, 690 V | 5 A |
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V | 6 A |
Rated operational current (Ie) at AC-4, 400 V | 6 A |
Rated operational current (Ie) at AC-4, 500 V | 5 A |
Rated operational current (Ie) at AC-4, 660 V, 690 V | 4.5 A |
Rated operational current (Ie) at DC-1, 60 V | 20 A |
Rated operational current (Ie) at DC-1, 110 V | 20 A |
Rated operational current (Ie) at DC-1, 220 V | 15 A |
Tensão nominal de isolamento (Ui) | 690 V |
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 22 A |
Rated operational power at AC-3, 240 V, 50 Hz | 3 kW |
Rated operational power at AC-3, 380/400 V, 50 Hz | 4 kW |
Rated operational power at AC-3, 415 V, 50 Hz | 5.5 kW |
Rated operational power at AC-4, 220/230 V, 50 Hz | 1.5 kW |
Rated operational power at AC-4, 240 V, 50 Hz | 1.6 kW |
Rated operational power at AC-4, 415 V, 50 Hz | 2.8 kW |
Rated operational power at AC-4, 440 V, 50 Hz | 3 kW |
Rated operational power at AC-4, 500 V, 50 Hz | 2.8 kW |
Rated operational power at AC-4, 660/690 V, 50 Hz | 3.6 kW |
Rated operational voltage (Ue) at AC – max | 690 V |
Short-circuit rating
Short-circuit current rating (basic rating) | 5 kA, SCCR (UL/CSA) 45 A, max. Fuse, SCCR (UL/CSA) 60 A, max. CB, SCCR (UL/CSA) |
Short-circuit current rating (high fault at 480 V) | 16 A, max. CB, SCCR (UL/CSA) 30/100 kA, Fuse, SCCR (UL/CSA) 65 kA, CB, SCCR (UL/CSA) 25 A, Class RK5/ 20 A Class J, max. Fuse, SCCR (UL/CSA) |
Short-circuit current rating (high fault at 600 V) | 25 A, Class RK5/20 A, Class J, max. Fuse, SCCR (UL/CSA) 30/100 kA, Fuse, SCCR (UL/CSA) |
Short-circuit protection rating (type 1 coordination) at 400 V | 35 A gG/gL |
Short-circuit protection rating (type 1 coordination) at 690 V | 20 A gG/gL |
Short-circuit protection rating (type 2 coordination) at 400 V | 20 A gG/gL |
Short-circuit protection rating (type 2 coordination) at 690 V | 16 A gG/gL |
Conventional thermal current
Conventional thermal current Ith (1-pole, enclosed) | 45 A |
Conventional thermal current Ith (3-pole, enclosed) | 18 A |
Conventional thermal current Ith at 55°C (3-pole, open) | 21 A |
Conventional thermal current Ith of main contacts (1-pole, open) | 50 A |
Switching capacity
Switching capacity (main contacts, general use) | 20 A, Maximum motor rating (UL/CSA) |
Switching capacity (auxiliary contacts, general use) | 1 A, 250 V DC, (UL/CSA) 10 A, 600 V AC, (UL/CSA) |
Switching capacity (auxiliary contacts, pilot duty) | A600, AC operated (UL/CSA) P300, DC operated (UL/CSA) |
Switching time
Arcing time | 10 ms |
Switching time (AC operated, make contacts, closing delay) – min | 15 ms |
Switching time (AC operated, make contacts, closing delay) – max | 21 ms |
Switching time (AC operated, make contacts, opening delay) – min | 9 ms |
Switching time (AC operated, make contacts, opening delay) – max | 18 ms |
Magnet system
Drop-out voltage | AC operated: 0.6 – 0.3 x UC, AC operated |
Duty factor | 100 % |
Pick-up voltage | 0.8 – 1.1 V AC x Uc |
Power consumption, pick-up, 50 Hz | 25 VA, Dual-frequency coil in a cold state and 1.0 x Us 27 VA, Dual-frequency coil in a cold state and 1.0 x Us |
Power consumption, pick-up, 60 Hz | 25 VA, Dual-frequency coil in a cold state and 1.0 x Us 27 VA, Dual-frequency coil in a cold state and 1.0 x Us |
Power consumption, sealing, 50 Hz | 1.2 W, Dual-frequency coil in a cold state and 1.0 x Us 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us |
Power consumption, sealing, 60 Hz | 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us 1.2 W, Dual-frequency coil in a cold state and 1.0 x Us 4.2 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz 3.3 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz |
Rated control supply voltage (Us) at AC, 50 Hz – min | 220 V |
Rated control supply voltage (Us) at AC, 50 Hz – max | 220 V |
Rated control supply voltage (Us) at AC, 60 Hz – min | 220 V |
Rated control supply voltage (Us) at AC, 60 Hz – max | 220 V |
Rated control supply voltage (Us) at DC – min | 0 V |
Rated control supply voltage (Us) at DC – max | 0 V |
Motor Rating
Assigned motor power at 115/120 V, 60 Hz, 1-phase | 0.5 HP |
Assigned motor power at 200/208 V, 60 Hz, 3-phase | 3 HP |
Assigned motor power at 230/240 V, 60 Hz, 1-phase | 1.5 HP |
Assigned motor power at 230/240 V, 60 Hz, 3-phase | 3 HP |
Assigned motor power at 460/480 V, 60 Hz, 3-phase | 5 HP |
Assigned motor power at 575/600 V, 60 Hz, 3-phase | 7.5 HP |
Communication
Connection to SmartWire-DT | No |
Contacts
Number of contacts (normally open contacts) | 1 |
Number of auxiliary contacts (normally closed contacts) | 0 |
Number of auxiliary contacts (normally open contacts) | 1 |
Safety
Safe isolation | 400 V AC, Between coil and contacts, According to EN 61140 400 V AC, Between the contacts, According to EN 61140 |
Special purpose ratings
Special purpose rating of ballast electrical discharge lamps | 18 A (480V 60Hz 3phase, 277V 60Hz 1phase) 18 A (600V 60Hz 3phase, 347V 60Hz 1phase) |
Special purpose rating of definite purpose rating | 54 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 9 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) |
Special purpose rating of elevator control | 6.1 A, 600 V 60 Hz 3-ph, (UL/CSA) 2 HP, 200 V 60 Hz 3-ph, (UL/CSA) 4.8 A, 480 V 60 Hz 3-ph, (UL/CSA) 5 HP, 600 V 60 Hz 3-ph, (UL/CSA) 2 HP, 240 V 60 Hz 3-ph, (UL/CSA) 7.8 A, 200 V 60 Hz 3-ph, (UL/CSA) 6.8 A, 240 V 60 Hz 3-ph, (UL/CSA) 3 HP, 480 V 60 Hz 3-ph, (UL/CSA) |
Special purpose rating of refrigeration control (CSA only) | 10 A, FLA 480 V 60 Hz 3phase; (CSA) 60 A, LRA 480 V 60 Hz 3phase; (CSA) 60 A, LRA 600 V 60 Hz 3phase; (CSA) 10 A, FLA 600 V 60 Hz 3phase; (CSA) |
Special purpose rating of resistance air heating | 18 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 18 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) |
Special purpose rating of tungsten incandescent lamps | 14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) 14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) |
Design verification
Equipment heat dissipation, current-dependent Pvid | 0 W |
Heat dissipation capacity Pdiss | 0 W |
Corrente operacional nominal para a dissipação de calor especificada (In) | 9 A |
10.2.2 Resistência à corrosão | Cumpre os requisitos da norma do produto. |
10.2.3.1 Verificação da estabilidade térmica dos invólucros | Cumpre os requisitos da norma do produto. |
10.2.3.2 Verificação da resistência dos materiais de isolamento ao calor normal | Cumpre os requisitos da norma do produto. |
10.2.3.3 Resistência do tapete de isolamento ao calor/incêndio anormal por efeitos eléctricos internos | Cumpre os requisitos da norma do produto. |
10.2.4 Resistência à radiação ultra-violeta (UV) | Cumpre os requisitos da norma do produto. |
10.2.5 Levantamento | Não se aplica, uma vez que é necessário avaliar todo o quadro elétrico. |
10.2.6 Impacto mecânico | Não se aplica, uma vez que é necessário avaliar todo o quadro elétrico. |
10.2.7 Inscrições | Cumpre os requisitos da norma do produto. |
10.3 Grau de proteção dos conjuntos | Não se aplica, uma vez que é necessário avaliar todo o quadro elétrico. |
10.4 Folgas e distâncias de fuga | Cumpre os requisitos da norma do produto. |
10.5 Proteção contra choques eléctricos | Não se aplica, uma vez que é necessário avaliar todo o quadro elétrico. |
10.6 Incorporação de dispositivos e componentes de comutação | Não se aplica, uma vez que é necessário avaliar todo o quadro elétrico. |
10.7 Circuitos eléctricos internos e ligações | É da responsabilidade do fabricante do painel. |
10.8 Ligações para condutores externos | É da responsabilidade do fabricante do painel. |
10.9.2 Força eléctrica de potência-frequência | É da responsabilidade do fabricante do painel. |
10.9.3 Tensão suportável de impulso | É da responsabilidade do fabricante do painel. |
10.9.4 Ensaio de invólucros feitos de material isolante | É da responsabilidade do fabricante do painel. |
10.10 Aumento da temperatura | O construtor do painel é responsável pelo cálculo do aumento de temperatura. A Eaton fornecerá os dados de dissipação de calor para os dispositivos. |
10.11 Classificação de curto-circuito | É da responsabilidade do construtor do quadro elétrico. As especificações do aparelho de distribuição devem ser respeitadas. |
10.12 Compatibilidade electromagnética | É da responsabilidade do construtor do quadro elétrico. As especificações do aparelho de distribuição devem ser respeitadas. |
10.13 Função mecânica | O aparelho cumpre os requisitos, desde que sejam respeitadas as informações do folheto de instruções (IL). |
Peso | 1 kg |
---|
Tem de iniciar sessão para enviar uma avaliação.


1. Processamento de encomendas: As encomendas são processadas no prazo de 1-2 dias úteis após a confirmação do pagamento. Os fins-de-semana e feriados estão excluídos do tempo de processamento.
2. Opções de envio e prazos :
a. Envio padrão: 3-7 dias úteis (varia consoante o destino).
b.Expedição acelerada: 2-3 dias úteis (aplicam-se taxas adicionais).
c.Envio internacional: 7-15 dias úteis (a alfândega pode afetar a entrega).
Notas:
Para artigos em stock, enviamos no prazo de 5 dias úteis após a receção do pagamento.
Os prazos de entrega de produtos fora de stock ou personalizados serão confirmados por correio eletrónico após a realização da encomenda.
3. Seguimento da sua encomenda: Receberá um número de seguimento por correio eletrónico assim que a sua encomenda for enviada. Utilize o nosso Portal do estado da encomenda para verificar as actualizações em tempo real.
4. Problemas de entrega?
Entregas falhadas: Contacte primeiro a sua transportadora local e depois contacte-nos.
Artigos errados/em falta? Envie-nos um e-mail no prazo de 7 dias após a entrega com os detalhes da encomenda.
5. Notas importantes Alfândegas e direitos aduaneiros: Os compradores internacionais são responsáveis por quaisquer taxas de importação.
Exatidão do endereço: Verifique novamente os seus dados de envio - não podemos modificar as encomendas depois de processadas!
Perguntas? Visite o nosso FAQs ou contactar: support@isscasolutions.com
Avaliações
Ainda não existem avaliações.