Eaton 277011 DILM17-10(220V50/60HZ) Contactor DILM, 220 V ac, 230 V dc Coil, 3-Pole, 3.5 kW, 1NC

$95.00

  • Número da peça: 277011 DILM17-10(220V50/60HZ)
  • Fabricante:Eaton
  • Disponibilidade: em stock
  • Tempo de espera estimado: Geralmente enviado em 1-5 dias úteis
  • Estado: Novíssimo
  • Garantia :12 meses

datasheet 277011 DILM17-10(220V50/60HZ)

REF: 277011 DILM17-10(220V50/60HZ) Categorias: , Etiqueta:
Descrição

General Specifications

Nome do produto
Eaton Moeller® series DILM contactor
Número de catálogo
277011
EAN
4015082770112
Comprimento/profundidade do produto
97 mm
Altura do produto
85 mm
Largura do produto
45 mm
Peso do produto
0.428 kg
Certificações
UL File No.: E29096
CSA Class No.: 2411-03, 3211-04
UL
CSA
VDE 0660
CSA File No.: 012528
IEC/EN 60947-4-1
CSA-C22.2 No. 60947-4-1-14
CE
IEC/EN 60947
UL 60947-4-1
UL Category Control No.: NLDX
Catalog Notes
Contacts according to EN 50012
Código do modelo
DILM17-10(220V50/60HZ)

Product specifications

Electrical connection type for auxiliary- and control-current circuit
Screw connection
Número de postes
Tripolar
Tensão nominal
220 V
10.10 Aumento da temperatura
O construtor do painel é responsável pelo cálculo do aumento de temperatura. A Eaton fornecerá os dados de dissipação de calor para os dispositivos.
10.11 Classificação de curto-circuito
É da responsabilidade do construtor do quadro elétrico. As especificações do aparelho de distribuição devem ser respeitadas.
10.12 Compatibilidade electromagnética
É da responsabilidade do construtor do quadro elétrico. As especificações do aparelho de distribuição devem ser respeitadas.
10.13 Função mecânica
O aparelho cumpre os requisitos, desde que sejam respeitadas as informações do folheto de instruções (IL).
10.2.2 Resistência à corrosão
Cumpre os requisitos da norma do produto.
10.2.3.1 Verificação da estabilidade térmica dos invólucros
Cumpre os requisitos da norma do produto.
10.2.3.2 Verificação da resistência dos materiais de isolamento ao calor normal
Cumpre os requisitos da norma do produto.
10.2.3.3 Resistência do tapete de isolamento ao calor/incêndio anormal por efeitos eléctricos internos
Cumpre os requisitos da norma do produto.
10.2.4 Resistência à radiação ultra-violeta (UV)
Cumpre os requisitos da norma do produto.
10.2.5 Levantamento
Não se aplica, uma vez que é necessário avaliar todo o quadro elétrico.
10.2.6 Impacto mecânico
Não se aplica, uma vez que é necessário avaliar todo o quadro elétrico.
10.2.7 Inscrições
Cumpre os requisitos da norma do produto.
10.3 Grau de proteção dos conjuntos
Não se aplica, uma vez que é necessário avaliar todo o quadro elétrico.
10.4 Folgas e distâncias de fuga
Cumpre os requisitos da norma do produto.
10.5 Proteção contra choques eléctricos
Não se aplica, uma vez que é necessário avaliar todo o quadro elétrico.
10.6 Incorporação de dispositivos e componentes de comutação
Não se aplica, uma vez que é necessário avaliar todo o quadro elétrico.
10.7 Circuitos eléctricos internos e ligações
É da responsabilidade do fabricante do painel.
10.8 Ligações para condutores externos
É da responsabilidade do fabricante do painel.
10.9.2 Força eléctrica de potência-frequência
É da responsabilidade do fabricante do painel.
10.9.3 Tensão suportável de impulso
É da responsabilidade do fabricante do painel.
10.9.4 Ensaio de invólucros feitos de material isolante
É da responsabilidade do fabricante do painel.
Frequency rating
50-60 Hz
Operating frequency
5000 mechanical Operations/h (AC operated)
Grau de poluição
3
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Connection to SmartWire-DT
No
Tensão nominal de resistência ao impulso (Uimp)
8000 V AC
Utilization category
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Connection
Terminais de parafuso
Frame size
FS2
Temperatura ambiente de funcionamento - máx
60 °C
Temperatura ambiente de funcionamento - min
-25 °C
Ambient operating temperature (enclosed) – max
40 °C
Ambient operating temperature (enclosed) – min
25 °C
Ambient storage temperature – max
80 °C
Ambient storage temperature – min
40 °C
Assigned motor power at 115/120 V, 60 Hz, 1-phase
2 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase
5 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase
3 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase
5 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase
10 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase
15 HP
Conventional thermal current Ith (1-pole, enclosed)
80 A
Conventional thermal current Ith (3-pole, enclosed)
32 A
Conventional thermal current Ith at 55°C (3-pole, open)
37 A
Conventional thermal current Ith of main contacts (1-pole, open)
88 A
Equipment heat dissipation, current-dependent Pvid
2.1 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.7 W
Aplicação
Contactors for Motors
Product category
Contactors
Protection
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Arcing time
10 ms
Electrical connection type of main circuit
Screw connection
Screwdriver size
2, Terminal screw, Pozidriv screwdriver
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Tipo de tensão
AC
Grau de proteção
IP00
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
1
Number of contacts (normally closed) as main contact
0
Number of contacts (normally open contacts)
1
Number of main contacts (normally open contact)
3
Rated breaking capacity at 220/230 V
170 A
Rated breaking capacity at 380/400 V
170 A
Rated breaking capacity at 500 V
170 A
Rated breaking capacity at 660/690 V
120 A
Rated control supply voltage (Us) at AC, 50 Hz – max
220 V
Rated control supply voltage (Us) at AC, 50 Hz – min
220 V
Rated control supply voltage (Us) at AC, 60 Hz – max
220 V
Rated control supply voltage (Us) at AC, 60 Hz – min
220 V
Contact configuration
1 NO
Drop-out voltage
AC operated: 0.6 – 0.3 x UC, AC operated
Categoria de sobretensão
III
Duty factor
100 %
Emitted interference
According to EN 60947-1
Interference immunity
According to EN 60947-1
Lifespan, mechanical
10,000,000 Operations (AC operated)
7,000,000 Operations (Coil 50/60 Hz)
Pick-up voltage
0.8 – 1.1 V AC x Uc
Power consumption, pick-up, 50 Hz
58 VA, Dual-frequency coil in a cold state and 1.0 x Us
62 VA, Dual-frequency coil in a cold state and 1.0 x Us
Safe isolation
440 V AC, Between the contacts, According to EN 61140
440 V AC, Between coil and contacts, According to EN 61140
Power consumption, pick-up, 60 Hz
62 VA, Dual-frequency coil in a cold state and 1.0 x Us
58 VA, Dual-frequency coil in a cold state and 1.0 x Us
Screw size
M5, Terminal screw, Main cables
M3.5, Terminal screw, Control circuit cables
Power consumption, sealing, 50 Hz
2.1 W, Dual-frequency coil in a cold state and 1.0 x Us
Power consumption, sealing, 60 Hz
2.1 W, Dual-frequency coil in a cold state and 1.0 x Us
6.5 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
9.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Terminal capacity (stranded)
1 x 16 mm², Main cables
Switching capacity (auxiliary contacts, general use)
10 A, 600 V AC, (UL/CSA)
1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)
P300, DC operated (UL/CSA)
A600, AC operated (UL/CSA)
Terminal capacity (flexible with ferrule)
2 x (0.75 – 10) mm², Main cables
2 x (0.75 – 2.5) mm², Control circuit cables
1 x (0.75 – 16) mm², Main cables
1 x (0.75 – 2.5) mm², Control circuit cables
Shock resistance
5.3 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
6.9 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
3.5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Terminal capacity (solid)
2 x (0.75 – 10) mm², Main cables
1 x (0.75 – 16) mm², Main cables
1 x (0.75 – 4) mm², Control circuit cables
2 x (0.75 – 2.5) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)
18 – 14, Control circuit cables
Single 18 – 6, double 18 – 8, Main cables
Switching capacity (main contacts, general use)
40 A, Maximum motor rating (UL/CSA)
Consumo de energia
7.5 kW
Tightening torque
3.2 Nm, Screw terminals, Main cables
1.2 Nm, Screw terminals, Control circuit cables
Rated control supply voltage (Us) at DC – max
0 V
Rated control supply voltage (Us) at DC – min
0 V
Tensão nominal de isolamento (Ui)
690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)
238 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
40 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
18 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
18 A
Rated operational current (Ie) at AC-3, 440 V
18 A
Rated operational current (Ie) at AC-3, 500 V
18 A
Rated operational current (Ie) at AC-3, 660 V, 690 V
12 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
10 A
Rated operational current (Ie) at AC-4, 400 V
10 A
Rated operational current (Ie) at AC-4, 440 V
10 A
Rated operational current (Ie) at AC-4, 500 V
10 A
Rated operational current (Ie) at AC-4, 660 V, 690 V
8 A
Rated operational current (Ie) at DC-1, 110 V
35 A
Rated operational current (Ie) at DC-1, 220 V
35 A
Rated operational current (Ie) at DC-1, 60 V
35 A
Corrente operacional nominal para a dissipação de calor especificada (In)
18 A
Rated operational power at AC-3, 240 V, 50 Hz
5.5 kW
Rated operational power at AC-3, 380/400 V, 50 Hz
7.5 kW
Rated operational power at AC-3, 415 V, 50 Hz
10 kW
Rated operational power at AC-4, 220/230 V, 50 Hz
2.5 kW
Rated operational power at AC-4, 240 V, 50 Hz
3 kW
Rated operational power at AC-4, 380/400 V, 50 Hz
4.5 kW
Rated operational power at AC-4, 415 V, 50 Hz
5 kW
Rated operational power at AC-4, 440 V, 50 Hz
5.5 kW
Rated operational power at AC-4, 500 V, 50 Hz
6 kW
Rated operational power at AC-4, 660/690 V, 50 Hz
6.5 kW
Rated operational power (NEMA)
7.4 kW
Rated operational voltage (Ue) at AC – max
690 V
Resistance per pole
2.7 mΩ
Static heat dissipation, non-current-dependent Pvs
2.1 W
Stripping length (control circuit cable)
10 mm
Stripping length (main cable)
10 mm
Switching time (AC operated, make contacts, closing delay) – max
22 ms
Switching time (AC operated, make contacts, closing delay) – min
16 ms
Switching time (AC operated, make contacts, opening delay) – max
14 ms
Switching time (AC operated, make contacts, opening delay) – min
8 ms
Short-circuit current rating (basic rating)
125 A, max. CB, SCCR (UL/CSA)
5 kA, SCCR (UL/CSA)
125 A, max. Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)
125/70 A, Class J, max. Fuse, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
10/65 kA, CB, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)
10/100 kA, Fuse, SCCR (UL/CSA)
125/70 A, Class J, max. Fuse, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
10/22 kA, CB, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V
63 A gG/gL
Suitable for
Also motors with efficiency class IE3
Short-circuit protection rating (type 1 coordination) at 690 V
50 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V
35 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V
35 A gG/gL
Special purpose rating of ballast electrical discharge lamps
40 A (600V 60Hz 3phase, 347V 60Hz 1phase)
40 A (480V 60Hz 3phase, 277V 60Hz 1phase)
Special purpose rating of definite purpose rating
108 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
18 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Special purpose rating of elevator control
11 A, 480 V 60 Hz 3-ph, (UL/CSA)
11 A, 600 V 60 Hz 3-ph, (UL/CSA)
11 A, 200 V 60 Hz 3-ph, (UL/CSA)
3 HP, 200 V 60 Hz 3-ph, (UL/CSA)
9.6 A, 240 V 60 Hz 3-ph, (UL/CSA)
3 HP, 240 V 60 Hz 3-ph, (UL/CSA)
7.5 HP, 480 V 60 Hz 3-ph, (UL/CSA)
10 HP, 600 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)
180 A, LRA 600 V 60 Hz 3phase; (CSA)
40 A, FLA 480 V 60 Hz 3phase; (CSA)
30 A, FLA 600 V 60 Hz 3phase; (CSA)
240 A, LRA 480 V 60 Hz 3phase; (CSA)
Special purpose rating of resistance air heating
40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
40 A, 600 V 60 Hz 3p
Informação adicional
Peso 1 kg
Dimensões (C x L x A) 30 × 15 × 15 cm
Avaliações (0)

Avaliações

Ainda não existem avaliações.

Seja o primeiro a avaliar “Eaton 277011 DILM17-10(220V50/60HZ) DILM Contactor, 220 V ac, 230 V dc Coil, 3-Pole, 3.5 kW, 1NC”
Expedição e entrega

1. Processamento de encomendas: As encomendas são processadas no prazo de 1-2 dias úteis após a confirmação do pagamento. Os fins-de-semana e feriados estão excluídos do tempo de processamento.
2. Opções de envio e prazos :
a. Envio padrão: 3-7 dias úteis (varia consoante o destino).
b.Expedição acelerada: 2-3 dias úteis (aplicam-se taxas adicionais).
c.Envio internacional: 7-15 dias úteis (a alfândega pode afetar a entrega).
Notas:
Para artigos em stock, enviamos no prazo de 5 dias úteis após a receção do pagamento.
Os prazos de entrega de produtos fora de stock ou personalizados serão confirmados por correio eletrónico após a realização da encomenda.
3. Seguimento da sua encomenda: Receberá um número de seguimento por correio eletrónico assim que a sua encomenda for enviada. Utilize o nosso Portal do estado da encomenda para verificar as actualizações em tempo real.
4. Problemas de entrega?
Entregas falhadas: Contacte primeiro a sua transportadora local e depois contacte-nos.
Artigos errados/em falta? Envie-nos um e-mail no prazo de 7 dias após a entrega com os detalhes da encomenda.
5. Notas importantes Alfândegas e direitos aduaneiros: Os compradores internacionais são responsáveis por quaisquer taxas de importação.
Exatidão do endereço: Verifique novamente os seus dados de envio - não podemos modificar as encomendas depois de processadas!

Perguntas? Visite o nosso FAQs ou contactar: support@isscasolutions.com